All Relations between planning and ct

Publication Sentence Publish Date Extraction Date Species
José A Peñagarícano, Chengyu Shi, Vancerat Ratanatharathor. Evaluation of integral dose in cranio-spinal axis (CSA) irradiation with conventional and helical delivery. Technology in cancer research & treatment. vol 4. issue 6. 2006-02-23. PMID:16292889. integral dose was calculated for organ at risk (oar), two targets (ptv-brain and ptv-spine), entire planning ct data set and to the healthy tissue (entire ct-data set minus the ptv). 2006-02-23 2023-08-12 Not clear
Shinichiro Mori, Ryosuke Kohno, Teiji Nishio, Hideyuki Mizuno, Hiroyo Yamashita, Yasushi Abe, Takeshi Ikeda, Toshihiro Ishihara, Hiroshi Asakura, Masahiro End. Physical evaluation of multidetector-row computed tomography (MDCT) scan methods and conditions for improvement of carbon beam distribution. Nihon Hoshasen Gijutsu Gakkai zasshi. vol 61. issue 12. 2006-02-17. PMID:16395235. not all institutes, however, can obtain thin slice ct images, and some have used thick slice ct images in planning. 2006-02-17 2023-08-12 Not clear
S Krarup, T A Darvann, P Larsen, J L Marsh, S Kreibor. Three-dimensional analysis of mandibular growth and tooth eruption. Journal of anatomy. vol 207. issue 5. 2006-02-09. PMID:16313399. as longitudinal ct data from normal children are not available (for ethical reasons), ct data from children with apert syndrome were employed, because it has been shown that the mandible in apert syndrome is unaffected by the malformation, and these children often have several craniofacial ct scans performed during childhood for planning of cranial and midface surgery and for follow-up after surgery. 2006-02-09 2023-08-12 Not clear
A Iwasaki, S Yamamoto, Y Yoshinaga, T Shirakus. [Review of the surgical treatment in superior sulcus tumor]. Kyobu geka. The Japanese journal of thoracic surgery. vol 59. issue 1. 2006-02-07. PMID:16440686. preoperative computed tomography (ct) or magnetic resonance imaging (mri) is beneficial to the evaluation of the vessels, nerves, and surgical planning. 2006-02-07 2023-08-12 Not clear
Massimo Bellomi, Guido Bonomo, Fabio Landoni, Gaetano Villa, Maria E Leon, Luca Bocciolone, Angelo Maggioni, Giuseppe Vial. Accuracy of computed tomography and magnetic resonance imaging in the detection of lymph node involvement in cervix carcinoma. European radiology. vol 15. issue 12. 2006-02-01. PMID:15999213. lymphnodes status in cervical carcinoma is important in therapeutic planning, and the role of computed tomography (ct) and magnetic resonance (mr) is controversial: this paper aims to evaluate their accuracy in diagnosing nodal metastases in patients with cervical carcinoma. 2006-02-01 2023-08-12 Not clear
Heikki Min. PET and SPECT in low-grade glioma. European journal of radiology. vol 56. issue 2. 2006-01-27. PMID:16233891. furthermore, for planning of lgg surgery or radiotherapy coregistration of functional images with ct and mri is invaluable. 2006-01-27 2023-08-12 Not clear
Gerasimos M Voros, Daniel Birchall, Thomas Ressiniotis, Christopher Neoh, Rona I Owen, Nicholas P Stron. Imaging of metastatic orbital leiomyosarcoma. Ophthalmic plastic and reconstructive surgery. vol 21. issue 6. 2006-01-24. PMID:16304527. the imaging characteristics of this rare tumor are comprehensively detailed, using complementary ultrasound, ct, and mri, the combination of which allowed planning of total excision of the lesion. 2006-01-24 2023-08-12 Not clear
Jonathan R Sykes, Ali Amer, Jadwiga Czajka, Christopher J Moor. A feasibility study for image guided radiotherapy using low dose, high speed, cone beam X-ray volumetric imaging. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 77. issue 1. 2006-01-10. PMID:16157400. image guidance of patient set-up for radiotherapy can be achieved by acquiring x-ray volumetric images (xvi) with elekta synergy and registering these to the planning ct scan. 2006-01-10 2023-08-12 Not clear
J-M Bachaud, D Marre, I Dygai, O Caselles, D Hamelin, M Bègue, A Laprie, S Zerdoud, M Gancel, F Courbo. [The impact of 18F-fluorodeoxyglucose positron emission tomography on the 3D conformal radiotherapy planning in patients with non-small cell lung cancer]. Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique. vol 9. issue 8. 2006-01-10. PMID:16316759. the co registration of fdg-pet images to the data of the ct planning offers the radiation oncologist the possibility to include functional information into the target outlining. 2006-01-10 2023-08-12 Not clear
Elisabeth Deniaud-Alexandre, Emmanuel Touboul, Delphine Lerouge, Dany Grahek, Jean-Noël Foulquier, Yolande Petegnief, Benoît Grès, Hanna El Balaa, Katia Keraudy, Kaldoun Kerrou, Françoise Montravers, Bernard Milleron, Bernard Lebeau, Jean-Noël Talbo. Impact of computed tomography and 18F-deoxyglucose coincidence detection emission tomography image fusion for optimization of conformal radiotherapy in non-small-cell lung cancer. International journal of radiation oncology, biology, physics. vol 63. issue 5. 2006-01-09. PMID:16125870. to report a retrospective study concerning the impact of fused 18f-fluoro-deoxy-d-glucose (fdg)-hybrid positron emission tomography (pet) and ct images on three-dimensional conformal radiotherapy planning for patients with non-small-cell lung cancer. 2006-01-09 2023-08-12 Not clear
Jarad M Martin, Daryl Lim Joon, Nicole Ng, Michael Grace, David Van Gelderen, Marita Lawlor, Morikatsu Wada, Michael Lim Joon, George Quong, Vincent Kho. Towards individualised radiotherapy for Stage I seminoma. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 76. issue 3. 2006-01-06. PMID:16169622. the use of computerised tomogram (ct) planning is compared with traditional planning for greater treatment individualisation. 2006-01-06 2023-08-12 Not clear
C Messa, G L Ceresoli, G Rizzo, D Artioli, M Cattaneo, P Castellone, V Gregorc, M Picchio, C Landoni, F Fazi. Feasibility of [18F]FDG-PET and coregistered CT on clinical target volume definition of advanced non-small cell lung cancer. The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of.... vol 49. issue 3. 2006-01-05. PMID:16172572. to prospectively evaluate the impact of coregistered positron emission tomography (pet) and computed tomography (ct) in 3d conformal radiotherapy (3d-crt) planning in patients with non-small lung cancer (nsclc). 2006-01-05 2023-08-12 Not clear
Jeremy Booth, Sergei Zavgorodn. Modelling the variation in rectal dose due to inter-fraction rectal wall deformation in external beam prostate treatments. Physics in medicine and biology. vol 50. issue 21. 2006-01-04. PMID:16237241. one of these is variation of the shape and position of the rectal wall (with respect to the clinical target volume (ctv)), which may differ daily from that taken during planning ct acquisition. 2006-01-04 2023-08-12 Not clear
Jeremy Booth, Sergei Zavgorodn. Modelling the variation in rectal dose due to inter-fraction rectal wall deformation in external beam prostate treatments. Physics in medicine and biology. vol 50. issue 21. 2006-01-04. PMID:16237241. the simulation of individual patients with full and empty rectum in the planning ct scan showed that large variations in rectal dose (>15 gy) are possible. 2006-01-04 2023-08-12 Not clear
Cheng B Saw, Alphonse Loper, Krishna Komanduri, Tony Combine, Saiful Huq, Carol Scicutell. Determination of CT-to-density conversion relationship for image-based treatment planning systems. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 30. issue 3. 2005-12-29. PMID:16112465. at the treatment planning workstation, the axial images were retrieved to determine the ct value of the inserts. 2005-12-29 2023-08-12 Not clear
Cheng B Saw, Alphonse Loper, Krishna Komanduri, Tony Combine, Saiful Huq, Carol Scicutell. Determination of CT-to-density conversion relationship for image-based treatment planning systems. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 30. issue 3. 2005-12-29. PMID:16112465. a new set of ct values vs. densities was generated from the bilinear equations and then entered into the treatment planning systems. 2005-12-29 2023-08-12 Not clear
Cheng B Saw, Alphonse Loper, Krishna Komanduri, Tony Combine, Saiful Huq, Carol Scicutell. Determination of CT-to-density conversion relationship for image-based treatment planning systems. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 30. issue 3. 2005-12-29. PMID:16112465. the need to obtain ct values through the treatment planning system is very clear. 2005-12-29 2023-08-12 Not clear
Cheng B Saw, Alphonse Loper, Krishna Komanduri, Tony Combine, Saiful Huq, Carol Scicutell. Determination of CT-to-density conversion relationship for image-based treatment planning systems. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 30. issue 3. 2005-12-29. PMID:16112465. the 2 treatment planning systems use different ct value ranges, one from -1024 to 3071 and the other from 0 to 4096. 2005-12-29 2023-08-12 Not clear
Cheng B Saw, Alphonse Loper, Krishna Komanduri, Tony Combine, Saiful Huq, Carol Scicutell. Determination of CT-to-density conversion relationship for image-based treatment planning systems. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 30. issue 3. 2005-12-29. PMID:16112465. in addition to the difference in the range of ct values, one treatment planning system uses physical density, while the other uses relative electron density. 2005-12-29 2023-08-12 Not clear
Hani Ashamalla, Sameer Rafla, Kapila Parikh, Bahaa Mokhtar, Ganesh Goswami, Shravan Kambam, Hussain Abdel-Dayem, Adel Guirguis, Pamela Ross, Alex Evol. The contribution of integrated PET/CT to the evolving definition of treatment volumes in radiation treatment planning in lung cancer. International journal of radiation oncology, biology, physics. vol 63. issue 4. 2005-12-27. PMID:15979817. by the use of (pet/computed tomography (ct) images in treatment planning, we were able to define a new gross treatment volume using anatomic biologic contour (abc), delineated directly on pet/ct images. 2005-12-27 2023-08-12 Not clear