All Relations between planning and ct

Publication Sentence Publish Date Extraction Date Species
Ambrose Chung-Wai Ho, Victor Ho-Fun Lee, Victor Shing-Howe To, Dora Lai-Wan Kwong, William Ignace We. Natural course and tumor doubling time of nasopharyngeal carcinoma. A study of 15 patients. Oral oncology. vol 47. issue 8. 2011-10-27. PMID:21708482. the time interval between the first planning ct image and the subsequent planning ct image was used to calculate the rate of tumor growth in this group of patients. 2011-10-27 2023-08-12 Not clear
Irina Vergalasova, Jacqueline Maurer, Fang-Fang Yi. Potential underestimation of the internal target volume (ITV) from free-breathing CBCT. Medical physics. vol 38. issue 8. 2011-10-25. PMID:21928643. localization prior to delivery of sbrt to free-breathing patients is performed by aligning the planning internal target volume (itv) from 4dct with an on-board free-breathing cone-beam ct (fb-cbct) image. 2011-10-25 2023-08-12 Not clear
W Zbijewski, P De Jean, P Prakash, Y Ding, J W Stayman, N Packard, R Senn, D Yang, J Yorkston, A Machado, J A Carrino, J H Siewerdse. A dedicated cone-beam CT system for musculoskeletal extremities imaging: design, optimization, and initial performance characterization. Medical physics. vol 38. issue 8. 2011-10-25. PMID:21928644. the system complements conventional ct and mr and offers a variety of potential clinical and logistical advantages that are likely to be of benefit to diagnosis, treatment planning, and assessment of therapy response in msk radiology, orthopaedic surgery, and rheumatology. 2011-10-25 2023-08-12 Not clear
C J Burke, R H Thomas, D Howlet. Imaging the major salivary glands. The British journal of oral & maxillofacial surgery. vol 49. issue 4. 2011-10-24. PMID:20381221. ultrasound (us), plain radiography and sialography, magnetic resonance imaging (mri), computed tomography (ct), and nuclear scintigraphy/positron emission tomography (pet) all play a part, and imaging often assists in the planning of further management, operative or otherwise. 2011-10-24 2023-08-12 Not clear
Feng Xiang Li, Jian Bin Li, Ying Jie Zhang, Tong Hai Liu, Shi Yu Tian, Min Xu, Dong Ping Shang, Chang Sheng M. Comparison of the planning target volume based on three-dimensional CT and four-dimensional CT images of non-small-cell lung cancer. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 99. issue 2. 2011-10-24. PMID:21549440. comparison of the planning target volume based on three-dimensional ct and four-dimensional ct images of non-small-cell lung cancer. 2011-10-24 2023-08-12 Not clear
Feng Xiang Li, Jian Bin Li, Ying Jie Zhang, Tong Hai Liu, Shi Yu Tian, Min Xu, Dong Ping Shang, Chang Sheng M. Comparison of the planning target volume based on three-dimensional CT and four-dimensional CT images of non-small-cell lung cancer. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 99. issue 2. 2011-10-24. PMID:21549440. to compare positional and volumetric differences of planning target volumes (ptvs) based on axial three-dimensional ct (3dct) and four-dimensional ct (4dct) for the primary tumor of non-small cell lung cancer (nsclc). 2011-10-24 2023-08-12 Not clear
Rebecca Muirhead, Lineke van der Weide, John R van Sornsen de Koste, Keith S Cover, Suresh Sena. Use of megavoltage cine-images for studying intra-thoracic motion during radiotherapy for locally advanced lung cancer. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. vol 99. issue 2. 2011-10-24. PMID:21621867. use of planning 4-dimensional ct (4dct) scans often permits use of smaller target volumes for thoracic tumors but this assumes a reproducible pattern of motion during radiotherapy. 2011-10-24 2023-08-12 Not clear
Andrej Terzic, Paolo Scolozz. Image guided surgical navigation integrating "mirroring" computational planning based on intra-operative cone-beam CT imaging: a promising new approach for management of primary bilateral midfacial fractures. Computer aided surgery : official journal of the International Society for Computer Aided Surgery. vol 16. issue 4. 2011-10-24. PMID:21675933. image guided surgical navigation integrating "mirroring" computational planning based on intra-operative cone-beam ct imaging: a promising new approach for management of primary bilateral midfacial fractures. 2011-10-24 2023-08-12 Not clear
Andrej Terzic, Paolo Scolozz. Image guided surgical navigation integrating "mirroring" computational planning based on intra-operative cone-beam CT imaging: a promising new approach for management of primary bilateral midfacial fractures. Computer aided surgery : official journal of the International Society for Computer Aided Surgery. vol 16. issue 4. 2011-10-24. PMID:21675933. so far, however, use of this approach has been limited to unilateral cases, with a non-fractured contralateral side being considered the condition sine qua non for the application of such a technique and the "mirroring" planning being performed on pre-operative ct imaging. 2011-10-24 2023-08-12 Not clear
Samuel España, Harald Paganett. Uncertainties in planned dose due to the limited voxel size of the planning CT when treating lung tumors with proton therapy. Physics in medicine and biology. vol 56. issue 13. 2011-10-21. PMID:21628773. uncertainties in planned dose due to the limited voxel size of the planning ct when treating lung tumors with proton therapy. 2011-10-21 2023-08-12 Not clear
Samuel España, Harald Paganett. Uncertainties in planned dose due to the limited voxel size of the planning CT when treating lung tumors with proton therapy. Physics in medicine and biology. vol 56. issue 13. 2011-10-21. PMID:21628773. the latter is not fully considered in the ct image resolution used in treatment planning causing the prediction of a more homogeneous tissue distribution. 2011-10-21 2023-08-12 Not clear
Samuel España, Harald Paganett. Uncertainties in planned dose due to the limited voxel size of the planning CT when treating lung tumors with proton therapy. Physics in medicine and biology. vol 56. issue 13. 2011-10-21. PMID:21628773. in conclusion, when assigning margins for treatment planning for lung cancer, proton range uncertainties due to the heterogeneous lung geometry and ct image resolution need to be considered. 2011-10-21 2023-08-12 Not clear
Jessica R Nieset, Joseph F Harmon, Susan M Laru. Use of cone-beam computed tomography to characterize daily urinary bladder variations during fractionated radiotherapy for canine bladder cancer. Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association. vol 52. issue 5. 2011-10-18. PMID:21699616. organs of interest were contoured on each cbct data set and the images, along with the contours, were registered to the original planning ct. all measurements were made relative to the planning ct and dosimetric data for the organs of interest was determined using a dose volume histogram generated from sample parallel-opposed beam configuration. 2011-10-18 2023-08-12 Not clear
S Hynds, C K McGarry, D M Mitchell, S Early, L Shum, D P Stewart, J A Harney, C R Cardwell, J M O'Sulliva. Assessing the daily consistency of bladder filling using an ultrasonic Bladderscan device in men receiving radical conformal radiotherapy for prostate cancer. The British journal of radiology. vol 84. issue 1005. 2011-10-14. PMID:21159811. this study evaluates the effectiveness of bladder-filling instructions in achieving a consistent and reproducible bladder volume at the time of planning ct and daily during the course of radical radiotherapy for prostate cancer. 2011-10-14 2023-08-12 Not clear
Yohei Bamba, Masahiro Nonaka, Shin Nakajima, Mami Yamasak. Three-dimensional reconstructed computed tomography-magnetic resonance fusion image-based preoperative planning for surgical procedures for spinal lipoma or tethered spinal cord after myelomeningocele repair. Neurologia medico-chirurgica. vol 51. issue 5. 2011-10-14. PMID:21613771. whereas two-dimensional images provide only limited information for surgical planning, three-dimensional (3d) reconstructed computed tomography (ct)-magnetic resonance (mr) fusion images produce clearer representations of the spinal regions. 2011-10-14 2023-08-12 Not clear
Vincent Wu, Matthew B Podgorsak, Tuan-Anh Tran, Harish K Malhotra, Iris Z Wan. Dosimetric impact of image artifact from a wide-bore CT scanner in radiotherapy treatment planning. Medical physics. vol 38. issue 7. 2011-10-05. PMID:21859046. dosimetric impact of image artifact from a wide-bore ct scanner in radiotherapy treatment planning. 2011-10-05 2023-08-12 Not clear
Vincent Wu, Matthew B Podgorsak, Tuan-Anh Tran, Harish K Malhotra, Iris Z Wan. Dosimetric impact of image artifact from a wide-bore CT scanner in radiotherapy treatment planning. Medical physics. vol 38. issue 7. 2011-10-05. PMID:21859046. the purpose of this study was to evaluate the dosimetric impact of image artifacts from efov reconstruction with a wide-bore ct scanner in radiotherapy (rt) treatment planning. 2011-10-05 2023-08-12 Not clear
Matteo Danza, Francesco Grecchi, Ilaria Zollino, Claudia Casadio, Francesco Carinc. Spiral implants bearing full-arch rehabilitation: analysis of clinical outcome. The Journal of oral implantology. vol 37. issue 4. 2011-09-27. PMID:20553144. several variables were investigated: demographic (age and gender), anatomic (maxilla and mandible, tooth site), implant (type, length, and diameter), surgical (surgeon, postextractive, flapless technique, grafts), and prosthetic (implant/crown ratio, dentition in the antagonist arch, type of loading, and computerized tomography [ct] planning) variables. 2011-09-27 2023-08-12 Not clear
Arpád Kovács, Lilla Tóth, Csaba Glavák, Ferenc Lakosi, Janaki Hadjiev, Gábor Bajzik, Csaba Vandulek, Imre Rep. Integrating functional MRI information into radiotherapy planning of CNS tumors-early experiences. Pathology oncology research : POR. vol 17. issue 2. 2011-09-27. PMID:20848253. before the planning process conventional planning ct, postoperative mr and individual functional mri examinations were delivered. 2011-09-27 2023-08-12 Not clear
Iskandar Kassim, Hans Joosten, Jaco C Barnhoorn, Ben J M Heijmen, Maarten L P Dirk. Implications of artefacts reduction in the planning CT originating from implanted fiducial markers. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 36. issue 2. 2011-09-26. PMID:20435466. implications of artefacts reduction in the planning ct originating from implanted fiducial markers. 2011-09-26 2023-08-12 Not clear