All Relations between planning and ct

Publication Sentence Publish Date Extraction Date Species
Luca Massimi, Massimo Caldarelli, Gianpiero Tamburrini, Giovanna Paternoster, Concezio Di Rocc. Isolated sagittal craniosynostosis: definition, classification, and surgical indications. Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery. vol 28. issue 9. 2013-01-15. PMID:22872242. however, a radiological work up (3d ct scan) may be necessary to rule out hidden venous or cranial anomalies possibly associated with most severe cases, or for the surgical planning. 2013-01-15 2023-08-12 human
Keiichi Nakagawa, Satoshi Kida, Akihiro Haga, Yoshitaka Masutani, Hideomi Yamashita, Tsuyoshi Onoe, Toshikazu Imae, Kenichiro Tanaka, Kuni Ohtomo, Kiyoshi Yod. 4D digitally reconstructed radiography for verifying a lung tumor position during volumetric modulated arc therapy. Journal of radiation research. vol 53. issue 4. 2013-01-10. PMID:22843630. an internal target volume (itv) was defined based on two clinical target volumes (ctvs) delineated on maximum exhalation and maximum inhalation images acquired by 4d planning computed tomography (ct). 2013-01-10 2023-08-12 Not clear
Keiichi Nakagawa, Satoshi Kida, Akihiro Haga, Yoshitaka Masutani, Hideomi Yamashita, Tsuyoshi Onoe, Toshikazu Imae, Kenichiro Tanaka, Kuni Ohtomo, Kiyoshi Yod. 4D digitally reconstructed radiography for verifying a lung tumor position during volumetric modulated arc therapy. Journal of radiation research. vol 53. issue 4. 2013-01-10. PMID:22843630. a planning target volume (ptv) was defined by adding a margin of 5 mm to the itv on the maximum exhalation 3d ct images. 2013-01-10 2023-08-12 Not clear
Hiroyuki Inoue, Masao Tanooka, Hiroshi Doi, Hideharu Miura, Hideo Nakagawa, Toshiyuki Sakai, Masahiko Oda, Katsumi Yasumasa, Kiyoshi Sakamoto, Norihiko Kamikonya, Shozo Hirot. [Impact of planning CT slice thickness on the accuracy of automatic target registration using the on-board cone-beam CT]. Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics. vol 31. issue 1. 2013-01-08. PMID:23002477. [impact of planning ct slice thickness on the accuracy of automatic target registration using the on-board cone-beam ct]. 2013-01-08 2023-08-12 Not clear
Hiroyuki Inoue, Masao Tanooka, Hiroshi Doi, Hideharu Miura, Hideo Nakagawa, Toshiyuki Sakai, Masahiko Oda, Katsumi Yasumasa, Kiyoshi Sakamoto, Norihiko Kamikonya, Shozo Hirot. [Impact of planning CT slice thickness on the accuracy of automatic target registration using the on-board cone-beam CT]. Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics. vol 31. issue 1. 2013-01-08. PMID:23002477. we have evaluated relationship between planning ct slice thickness and the accuracy of automatic target registration using cone-beam ct (cbct). 2013-01-08 2023-08-12 Not clear
Hiroyuki Inoue, Masao Tanooka, Hiroshi Doi, Hideharu Miura, Hideo Nakagawa, Toshiyuki Sakai, Masahiko Oda, Katsumi Yasumasa, Kiyoshi Sakamoto, Norihiko Kamikonya, Shozo Hirot. [Impact of planning CT slice thickness on the accuracy of automatic target registration using the on-board cone-beam CT]. Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics. vol 31. issue 1. 2013-01-08. PMID:23002477. planning ct images were acquired with reconstructed slice thickness of 1, 2, 3, 5, and 10mm for three different phantoms: penta-guide phantom, acrylic ball phantom, and pelvic phantom. 2013-01-08 2023-08-12 Not clear
Hiroyuki Inoue, Masao Tanooka, Hiroshi Doi, Hideharu Miura, Hideo Nakagawa, Toshiyuki Sakai, Masahiko Oda, Katsumi Yasumasa, Kiyoshi Sakamoto, Norihiko Kamikonya, Shozo Hirot. [Impact of planning CT slice thickness on the accuracy of automatic target registration using the on-board cone-beam CT]. Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics. vol 31. issue 1. 2013-01-08. PMID:23002477. registration between the planning ct and the cbct was performed using automatic target registration software, and the registration errors were recorded for each planning ct data set with different slice thickness. 2013-01-08 2023-08-12 Not clear
Hiroyuki Inoue, Masao Tanooka, Hiroshi Doi, Hideharu Miura, Hideo Nakagawa, Toshiyuki Sakai, Masahiko Oda, Katsumi Yasumasa, Kiyoshi Sakamoto, Norihiko Kamikonya, Shozo Hirot. [Impact of planning CT slice thickness on the accuracy of automatic target registration using the on-board cone-beam CT]. Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics. vol 31. issue 1. 2013-01-08. PMID:23002477. the results suggest that there is no obvious correlation between the planning ct slice thickness and the registration errors. 2013-01-08 2023-08-12 Not clear
Michael Engel, Juergen Hoffmann, Joachim Mühling, Gregor Castrillón-Oberndorfer, Robin Seeberger, Christian Freudlsperge. Magnetic resonance imaging in isolated sagittal synostosis. The Journal of craniofacial surgery. vol 23. issue 4. 2013-01-07. PMID:22801186. although the typical clinical appearance usually points the way to the right diagnosis, computed tomographic (ct) scans are still recommended as necessary tools for both the diagnosis of scaphocephaly and the preoperative planning. 2013-01-07 2023-08-12 Not clear
David G Pennington, Philip Rome, Peter Kitchene. Predicting results of DIEP flap reconstruction: the flap viability index. Journal of plastic, reconstructive & aesthetic surgery : JPRAS. vol 65. issue 11. 2013-01-04. PMID:22704607. ct angiographic vascular imaging has enhanced the planning of reconstruction, allowing mapping of perforator patterns to increase the predictability of surgery. 2013-01-04 2023-08-12 Not clear
Shamurailatpam Dayananda Sharma, Prabhakar Dongre, Vaibhav Mhatre, Malhotra Heigruja. Evaluation of automated image registration algorithm for image-guided radiotherapy (IGRT). Australasian physical & engineering sciences in medicine. vol 35. issue 3. 2013-01-03. PMID:22948720. the orthogonal radiographs and cbcts were automatically co-registered to reference digitally reconstructed radiographs (drrs) and planning ct using 2d-2d and 3d-3d matching software based on mutual information transformation. 2013-01-03 2023-08-12 Not clear
Shamurailatpam Dayananda Sharma, Prabhakar Dongre, Vaibhav Mhatre, Malhotra Heigruja. Evaluation of automated image registration algorithm for image-guided radiotherapy (IGRT). Australasian physical & engineering sciences in medicine. vol 35. issue 3. 2013-01-03. PMID:22948720. the reproducibility of automatic ir of planning ct and repeat cbcts taken with and without kilovoltage detector and kilovoltage x-ray source arm movement was excellent with mean sd of 0.1 mm in the translation and 0.0° in rotation. 2013-01-03 2023-08-12 Not clear
N Willic. [Technical and methodical developments of radiation oncology from a physician's point of view]. Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]. vol 188 Suppl 3. 2013-01-02. PMID:22895626. modern imaging methods, e.g., computed tomography (ct), magnetic resonance imaging (mri), positron emission tomography (pet), and ultrasound (us), have not only improved the detection of tumors but have also become tools for computed treatment planning. 2013-01-02 2023-08-12 Not clear
Austin S Adams, Mary J Wright, Sean Johnston, Ravi Tandon, Neel Gupta, Kenneth Ward, Cynthia Hanemann, Enrique Palacios, Paul L Friedlander, Ernest S Chi. The use of multislice CT angiography preoperative study for supraclavicular artery island flap harvesting. Annals of plastic surgery. vol 69. issue 3. 2012-12-31. PMID:21825967. the objective of this report is to demonstrate the utility of multislice computed tomography (ct) angiography for confirming the presence of the vascular pedicle of the sai flap when planning head and neck reconstruction. 2012-12-31 2023-08-12 Not clear
Marc Sarti, William P Brehmer, Spencer B Ga. Low-dose techniques in CT-guided interventions. Radiographics : a review publication of the Radiological Society of North America, Inc. vol 32. issue 4. 2012-12-12. PMID:22786997. methods to reduce radiation exposure in patients and physicians include performing proper preprocedure planning and paying careful attention to technique during the planning stage, making use of personal protective equipment, performing ct fluoroscopy intermittently instead of in real time, and optimizing needle visualization. 2012-12-12 2023-08-12 Not clear
Dengwang Li, Hongsheng Li, Honglin Wan, Jinhu Chen, Guanzhong Gong, Hongjun Wang, Liming Wang, Yong Yi. Multiscale registration of medical images based on edge preserving scale space with application in image-guided radiation therapy. Physics in medicine and biology. vol 57. issue 16. 2012-12-06. PMID:22842788. furthermore, clinical application by adaptive gross tumor volume re-contouring for clinical pet/ct image-guided radiation therapy throughout the course of radiotherapy is also studied, and the overlap between the automatically generated contours for the ct image and the contours delineated by the oncologist used for the planning system are on average 90%. 2012-12-06 2023-08-12 Not clear
Robert A Magnussen, Pedro Debieux, Biju Benjamin, Sébastien Lustig, Guillaume Demey, Elvire Servien, Philippe Neyre. A CT-based classification of prior ACL femoral tunnel location for planning revision ACL surgery. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. vol 20. issue 7. 2012-12-03. PMID:22159522. the purposes of this study are to describe an acl femoral tunnel classification system for use in planning revision acl reconstruction based on 3-d computed tomography (ct) reconstructions and to evaluate its inter- and intra-rater reliability. 2012-12-03 2023-08-12 Not clear
Prabhjot Juneja, Emma J Harris, Anna M Kirby, Philip M Evan. Adaptive breast radiation therapy using modeling of tissue mechanics: a breast tissue segmentation study. International journal of radiation oncology, biology, physics. vol 84. issue 3. 2012-11-30. PMID:22717244. to validate and compare the accuracy of breast tissue segmentation methods applied to computed tomography (ct) scans used for radiation therapy planning and to study the effect of tissue distribution on the segmentation accuracy for the purpose of developing models for use in adaptive breast radiation therapy. 2012-11-30 2023-08-12 Not clear
Takaaki Fujii, Satoru Yamaguchi, Reina Yajima, Soichi Tsutsumi, Takayuki Asao, Hiroyuki Kuwan. Accurate assessment of breast volume by computed tomography using three-dimensional imaging device. The American surgeon. vol 78. issue 9. 2012-11-29. PMID:22964199. our results suggest that the calculation of breast volume using three-dimensional ct is accurate enough to have a significant clinical benefit in planning reconstructive breast surgery. 2012-11-29 2023-08-12 Not clear
Pengjun Su, Ying Huang, Weilin Wang, Zhibo Zhan. The value of preoperative CT scan in newborns with type C esophageal atresia. Pediatric surgery international. vol 28. issue 7. 2012-11-26. PMID:22491897. this study was designed to evaluate the accuracy of preoperative ct scan in depicting the structure of type c esophageal atresia (ea) and determine its role in planning the surgical strategy by digitally measuring the interpouch distance. 2012-11-26 2023-08-12 Not clear