All Relations between planning and ct

Publication Sentence Publish Date Extraction Date Species
P K Saha, G Liang, J M Elkins, A Coimbra, L T Duong, D S Williams, M Sonk. A new osteophyte segmentation algorithm using partial shape model and its applications to rabbit femur anterior cruciate ligament transection via micro-CT imaging. IEEE transactions on bio-medical engineering. vol 58. issue 8. 2014-03-03. PMID:21421428. detection and quantification of osteophytes from ct images is helpful in assessing disease status as well as treatment and surgery planning. 2014-03-03 2023-08-12 rabbit
Mohammad Bakhtiari, Ashkan Parniani, Fritz Lerma, Shannon Reynolds, James Jordan, Alireza Sedaghat, Mehrdad Sarfaraz, James Rodger. Evaluation of a software system for estimating planned dose error in patients, based on planar IMRT QA measurements. Radiology and oncology. vol 48. issue 1. 2014-03-03. PMID:24587785. techniques and software systems are commercially available which use individual field dosimetry measurements as input into algorithms that estimate 3d patient dose distributions on ct scan derived target volumes and organs at risk (oars), thus allowing direct dose-volume histogram (dvh) analysis vs. treatment planning system (tps) dvh. 2014-03-03 2023-08-12 Not clear
Cory Collinge, Jason Kennedy, Andrew Schmid. Temporizing external fixation of the lower extremity: a survey of the orthopaedic trauma association membership. Orthopedics. vol 33. issue 4. 2014-02-28. PMID:20415303. among the strongest preferences (rating average >4) were for obtaining a computed tomography (ct) scan as part of prereconstruction planning (4.8) and obtaining that ct scan after joint-spanning external fixation was applied (4.6). 2014-02-28 2023-08-12 Not clear
Thomas Fortin, Elsa Camby, Mahdi Alik, Michel Isidori, Hervé Bouche. Panoramic images versus three-dimensional planning software for oral implant planning in atrophied posterior maxillary: a clinical radiological study. Clinical implant dentistry and related research. vol 15. issue 2. 2014-02-28. PMID:21477064. the objectives of this radiographic study were to determine to what degree the available residual bone area for implant placement was underestimated on panoramic radiographs (by comparison with multislice computed tomography ct/cone beam ct images combined with planning software) and to what degree the rate of severely resorbed posterior maxillae requiring sinus lift was overestimated on panoramic radiographs (by comparison with planning software in combination with strategic implant placement). 2014-02-28 2023-08-12 Not clear
Antonio Rivas-Garcia, Silvana Sarria-Estrada, Carme Torrents-Odin, Lourdes Casas-Gomila, Elisa Franque. Imaging findings of Pott's disease. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. vol 22 Suppl 4. 2014-02-28. PMID:22684257. advanced imaging such as magnetic resonance imaging (mri), multidetector computed tomography (mdct) and fluor18-deoxiglucose positron emission tomography combined with ct (f-18 fdg pet-ct) demonstrate lesion extent, serve as guide for biopsy with aspiration for culture, assist surgery planning and contribute to follow-up. 2014-02-28 2023-08-12 Not clear
L Evangelista, C Mezzato, G Felloni, G Saladin. Current and future perspectives in diagnostic imaging as a guide to targeted/local therapies in breast cancer recurrence. The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of.... vol 57. issue 4. 2014-02-27. PMID:24322793. the introduction of positron emission tomography (pet) and pet/computed tomography (ct) with 18f-fluorodeoxyglucose and other radiolabelled molecules for the early detection of breast cancer recurrence has important consequences both for staging and treatment planning. 2014-02-27 2023-08-12 Not clear
Tiancheng He, Zhong Xue, Paige L Nitsch, Bin S Teh, Stephen T Won. Helical mode lung 4D-CT reconstruction using Bayesian model. Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention. vol 16. issue Pt 3. 2014-02-27. PMID:24505741. 4d computed tomography (ct) has been widely used for treatment planning of thoracic and abdominal cancer radiotherapy. 2014-02-27 2023-08-12 human
Christian Wachinger, Gregory C Sharp, Polina Gollan. Contour-driven regression for label inference in atlas-based segmentation. Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention. vol 16. issue Pt 3. 2014-02-27. PMID:24505763. we focus on the segmentation of parotid glands in ct scans of patients with head and neck cancer, which is important for radiation therapy planning. 2014-02-27 2023-08-12 Not clear
Sara Janek Strååt, Björn Andreassen, Cathrine Jonsson, Marilyn E Noz, Gerald Q Maguire, Peder Näfstadius, Ingemar Näslund, Frederic Schoenahl, Anders Brahm. Clinical application of in vivo treatment delivery verification based on PET/CT imaging of positron activity induced at high energy photon therapy. Physics in medicine and biology. vol 58. issue 16. 2014-02-20. PMID:23880661. the ct volume from the pet/ct and the treatment planning ct were coregistered by matching anatomical reference points in the patient. 2014-02-20 2023-08-12 Not clear
Oliver J Gurney-Champion, Max Dahele, Hassan Mostafavi, Ben J Slotman, Wilko F A R Verbake. Digital tomosynthesis for verifying spine position during radiotherapy: a phantom study. Physics in medicine and biology. vol 58. issue 16. 2014-02-20. PMID:23902917. each dts slice was registered to a digitally reconstructed dts derived from the planning ct scan to determine 2d shifts between actual phantom and treatment plan position. 2014-02-20 2023-08-12 Not clear
Adrian A Wong, Resmi A Charalel, John D Louie, Daniel Y Sz. Carbon dioxide contrast enhancement for C-arm CT utility for treatment planning during hepatic embolization procedures. Journal of vascular and interventional radiology : JVIR. vol 24. issue 7. 2014-02-14. PMID:23796085. carbon dioxide contrast enhancement for c-arm ct utility for treatment planning during hepatic embolization procedures. 2014-02-14 2023-08-12 Not clear
B Zurl, R Tiefling, P Winkler, P Kindl, K S Kap. Hounsfield units variations: impact on CT-density based conversion tables and their effects on dose distribution. Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]. vol 190. issue 1. 2014-02-11. PMID:24201381. determination of dose error margins in radiation therapy planning due to variations in hounsfield units (hu) values dependent on the use of different ct scanning protocols. 2014-02-11 2023-08-12 Not clear
P J Hoskin, P Díez, M Williams, H Lucraft, M Bayn. Recommendations for the use of radiotherapy in nodal lymphoma. Clinical oncology (Royal College of Radiologists (Great Britain)). vol 25. issue 1. 2014-02-07. PMID:22889569. both wide-field and involved-field techniques have now been supplanted by the use of defined volumes based on node involvement shown on computed tomography (ct) and positron emission tomography (pet) imaging and applying the international commission on radiation units and measurements concepts of gross tumour volume (gtv), clinical target volume (ctv) and planning target volume (ptv). 2014-02-07 2023-08-12 Not clear
P J Hoskin, P Díez, M Williams, H Lucraft, M Bayn. Recommendations for the use of radiotherapy in nodal lymphoma. Clinical oncology (Royal College of Radiologists (Great Britain)). vol 25. issue 1. 2014-02-07. PMID:22889569. the planning of lymphoma patients for radical radiotherapy should now be based upon contrast enhanced 3 mm contiguous ct with three-dimensional definition of volumes using the convention of gtv, ctv and ptv. 2014-02-07 2023-08-12 Not clear
Bernhard Bischoff, Felix G Meinel, Maximilian Reiser, Hans-Christoph Becke. Novel single-source high-pitch protocol for CT angiography of the aorta: comparison to high-pitch dual-source protocol in the context of TAVI planning. The international journal of cardiovascular imaging. vol 29. issue 5. 2014-02-07. PMID:23334190. novel single-source high-pitch protocol for ct angiography of the aorta: comparison to high-pitch dual-source protocol in the context of tavi planning. 2014-02-07 2023-08-12 Not clear
Bernhard Bischoff, Felix G Meinel, Maximilian Reiser, Hans-Christoph Becke. Novel single-source high-pitch protocol for CT angiography of the aorta: comparison to high-pitch dual-source protocol in the context of TAVI planning. The international journal of cardiovascular imaging. vol 29. issue 5. 2014-02-07. PMID:23334190. purpose computed tomography (ct) is increasingly being used for planning purposes prior to trans-arterial valve implantation (tavi). 2014-02-07 2023-08-12 Not clear
Bernhard Bischoff, Felix G Meinel, Maximilian Reiser, Hans-Christoph Becke. Novel single-source high-pitch protocol for CT angiography of the aorta: comparison to high-pitch dual-source protocol in the context of TAVI planning. The international journal of cardiovascular imaging. vol 29. issue 5. 2014-02-07. PMID:23334190. conclusions this study presents a novel high-pitch protocol for modern ssct scanners, which allows ct angiography for tavi planning with a similar radiation dose and contrast agent exposition and only small compromises in image quality compared to a high-pitch protocol on a dsct scanner. 2014-02-07 2023-08-12 Not clear
Hiroto Yoshikawa, Elissa K Randall, Susan L Kraft, Susan M Laru. Comparison between 2-(18) F-fluoro-2-deoxy-d-glucose positron emission tomography and contrast-enhanced computed tomography for measuring gross tumor volume in cats with oral squamous cell carcinoma. Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association. vol 54. issue 3. 2014-02-07. PMID:23441633. the goal of the current prospective study was to compare gross tumor volume measurements using (18) f-fdg pet vs. those using computed tomography (ct) for stereotactic radiation therapy planning in cats with oral squamous cell carcinoma. 2014-02-07 2023-08-12 Not clear
Mutsumi Tashiro, Takayoshi Ishii, Jun-ichi Koya, Ryosuke Okada, Yuji Kurosawa, Keisuke Arai, Satoshi Abe, Yoshiaki Ohashi, Hirofumi Shimada, Ken Yusa, Tatsuaki Kanai, Satoru Yamada, Hidemasa Kawamura, Takeshi Ebara, Tatsuya Ohno, Takashi Nakan. Technical approach to individualized respiratory-gated carbon-ion therapy for mobile organs. Radiological physics and technology. vol 6. issue 2. 2014-02-04. PMID:23568337. gated computed tomography (ct) scans were used for treatment planning, and four-dimensional (4d) ct scans were used to evaluate motion errors within the gating window to help define the internal margins (ims) and planning target volume for each patient. 2014-02-04 2023-08-12 Not clear
Sarfraz Ahmed Nazir, Rachel Benamore, Fergus Gleeso. Missed lung cancers on the scout view: do we look every time? Case reports in medicine. vol 2013. 2014-02-03. PMID:24489553. scout views are digital radiographs obtained to aid planning of the subsequent computed tomography (ct) examination. 2014-02-03 2023-08-12 Not clear