All Relations between planning and ct

Publication Sentence Publish Date Extraction Date Species
Aurora Fassi, Matteo Seregni, Marco Riboldi, Pietro Cerveri, David Sarrut, Giovanni Battista Ivaldi, Paola Tabarelli de Fatis, Marco Liotta, Guido Baron. Surrogate-driven deformable motion model for organ motion tracking in particle radiation therapy. Physics in medicine and biology. vol 60. issue 4. 2016-01-18. PMID:25615399. differently from current tracking methods applied in conventional radiotherapy, the proposed approach allows for the dynamic localization of all anatomical structures scanned in the planning ct, thus providing complete information on density and wel variations required for particle beam range adaptation. 2016-01-18 2023-08-13 Not clear
E Kaza, R Symonds-Tayler, D J Collins, F McDonald, H A McNair, E Scurr, D-M Koh, M O Leac. First MRI application of an active breathing coordinator. Physics in medicine and biology. vol 60. issue 4. 2016-01-18. PMID:25633183. this demonstrates the value of abc, since application of t1, t2 and diffusion weighted mr sequences provides a wider range of contrast mechanisms and additional diagnostic information compared to ct, thus improving radiotherapy treatment planning and assessment. 2016-01-18 2023-08-13 human
Chong Zou, Feng Niu, Bing Yu, Jian-Feng Liu, Lai Gu. Zygomatic Complex Change After Reduction Malarplasty and Its Geometric Model: A Retrospective Clinical Study. Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons. vol 73. issue 11. 2016-01-18. PMID:25959875. this study aimed to analyze the associations between the width of bony resection and changes in zygomatic bony parameters, to propose a geometric model to guide surgical planning, and to objectively evaluate the surgical outcomes of reduction malarplasty based on computed tomographic (ct) images. 2016-01-18 2023-08-13 Not clear
Minh Tam Truong, Nataliya Kovalchu. Radiotherapy planning. PET clinics. vol 10. issue 2. 2016-01-15. PMID:25829092. incorporation of pet/computed tomography (ct) in radiotherapy planning plays a critical role in assisting gross tumor volume delineation for radiotherapy planning and delivery. 2016-01-15 2023-08-13 Not clear
Changsheng Ma, Jianping Cao, Yong Yin, Jian Zh. Radiotherapy dose calculation on KV cone-beam CT image for lung tumor using the CIRS calibration. Thoracic cancer. vol 5. issue 1. 2016-01-15. PMID:26766975. a clinical treatment planning system was employed for ct and kv cbct image to dose calculations and subsequent comparisons. 2016-01-15 2023-08-13 Not clear
Lin Su, Xian-Jun Zhou, Qian Dong, Hong Zhang, Feng Shen, Yong-Jian Chen, Xi-Wei Hao, Xiao-Fei L. Application value of computer assisted surgery system in precision surgeries for pediatric complex liver tumors. International journal of clinical and experimental medicine. vol 8. issue 10. 2016-01-15. PMID:26770445. higemi was used for 3-dimensional (3d) reconstruction of thin-slice ct images and surgical planning. 2016-01-15 2023-08-13 Not clear
Vasant Kearney, Susie Chen, Xuejun Gu, Tsuicheng Chiu, Honghuan Liu, Lan Jiang, Jing Wang, John Yordy, Lucien Nedzi, Weihua Ma. Automated landmark-guided deformable image registration. Physics in medicine and biology. vol 60. issue 1. 2016-01-12. PMID:25479095. the purpose of this work is to develop an automated landmark-guided deformable image registration (ldir) algorithm between the planning ct and daily cone-beam ct (cbct) with low image quality. 2016-01-12 2023-08-13 Not clear
Vasant Kearney, Susie Chen, Xuejun Gu, Tsuicheng Chiu, Honghuan Liu, Lan Jiang, Jing Wang, John Yordy, Lucien Nedzi, Weihua Ma. Automated landmark-guided deformable image registration. Physics in medicine and biology. vol 60. issue 1. 2016-01-12. PMID:25479095. this method uses an automated landmark generation algorithm in conjunction with a local small volume gradient matching search engine to map corresponding landmarks between the cbct and the planning ct. 2016-01-12 2023-08-13 Not clear
Pedro Andre. Dose to 'water-like' media or dose to tissue in MV photons radiotherapy treatment planning: still a matter of debate. Physics in medicine and biology. vol 60. issue 1. 2016-01-12. PMID:25503312. the difference between monte carlo treatment planning (mctp) based on the assumption of 'water-like' tissues with densities obtained from ct procedures, or on tissue compositions derived from ct-determined densities, have been investigated. 2016-01-12 2023-08-13 Not clear
Yuan Xu, Ti Bai, Hao Yan, Luo Ouyang, Arnold Pompos, Jing Wang, Linghong Zhou, Steve B Jiang, Xun Ji. A practical cone-beam CT scatter correction method with optimized Monte Carlo simulations for image-guided radiation therapy. Physics in medicine and biology. vol 60. issue 9. 2016-01-06. PMID:25860299. in contrast with conventional mc approaches that estimate scatter signals using a scatter-contaminated cbct image, our method used a planning ct image for mc simulation, which has the advantages of accurate image intensity and absence of image truncation. 2016-01-06 2023-08-13 Not clear
Yuan Xu, Ti Bai, Hao Yan, Luo Ouyang, Arnold Pompos, Jing Wang, Linghong Zhou, Steve B Jiang, Xun Ji. A practical cone-beam CT scatter correction method with optimized Monte Carlo simulations for image-guided radiation therapy. Physics in medicine and biology. vol 60. issue 9. 2016-01-06. PMID:25860299. in our method, the planning ct was first rigidly registered with the cbct. 2016-01-06 2023-08-13 Not clear
Romain Brevet, Daniel Richter, Christian Graeff, Marco Durante, Christoph Ber. Treatment Parameters Optimization to Compensate for Interfractional Anatomy Variability and Intrafractional Tumor Motion. Frontiers in oncology. vol 5. 2016-01-06. PMID:26734573. using the gsi in-house treatment planning system trip4d, 4d simulations were performed on each weekly 4dct for each patient using gating and optimization of a single treatment plan based on a planning ct acquired prior to treatment. 2016-01-06 2023-08-13 Not clear
Joao Seco, Ben Clasie, Mike Partridg. Review on the characteristics of radiation detectors for dosimetry and imaging. Physics in medicine and biology. vol 59. issue 20. 2016-01-04. PMID:25229250. these huge advances in imaging have enabled equally impressive steps forward in radiotherapy delivery accuracy, with 4dct, pet and mri routinely used in treatment planning and online image guidance provided by cone-beam ct. 2016-01-04 2023-08-13 human
Hirofumi Tominaga, Fujio Araki, Yoshinobu Shimohigashi, Terunobu Ishihara, Keiichi Kawasaki, Nagisa Kanetake, Junichi Sakata, Yuki Iwashit. Accuracy of positioning and irradiation targeting for multiple targets in intracranial image-guided radiation therapy: a phantom study. Physics in medicine and biology. vol 59. issue 24. 2016-01-04. PMID:25419723. the positioning accuracy was determined from the deviations of coordinates of the central point in each target obtained from the kv-cone beam computed tomography (kv-cbct) for igrt and the planning ct. 2016-01-04 2023-08-13 Not clear
Christiaan Ja van Bergen, Rogier M Gerards, Kim Tm Opdam, Maaike P Terra, Gino Mmj Kerkhoff. Diagnosing, planning and evaluating osteochondral ankle defects with imaging modalities. World journal of orthopedics. vol 6. issue 11. 2015-12-30. PMID:26716090. ct with the ankle in full plantar flexion has been shown a reliable tool for preoperative planning of the surgical approach. 2015-12-30 2023-08-13 Not clear
Alexander Huppertz, Alexander Lembcke, El-Hadi Sariali, Tahir Durmus, Carsten Schwenke, Bernd Hamm, Martin Sparmann, Alexander D J Bau. Low Dose Computed Tomography for 3D Planning of Total Hip Arthroplasty: Evaluation of Radiation Exposure and Image Quality. Journal of computer assisted tomography. vol 39. issue 5. 2015-12-29. PMID:26125297. the aim of the study was to compare radiation exposure and image quality between dedicated computed tomography (ct) protocols for preoperative total hip arthroplasty (tha) planning. 2015-12-29 2023-08-13 Not clear
Helen A McNair, Emma J Harris, Vibeke N Hansen, Karen Thomas, Christopher South, Shaista Hafeez, Robert Huddart, David P Dearnale. Magnitude of observer error using cone beam CT for prostate interfraction motion estimation: effect of reducing scan length or increasing exposure. The British journal of radiology. vol 88. issue 1054. 2015-12-29. PMID:26246041. cone beam ct (cbct) enables soft-tissue registration to planning ct for position verification in radiotherapy. 2015-12-29 2023-08-13 Not clear
Josefine S Kornerup, Patrik Brodin, Charlotte Birk Christensen, Thomas Björk-Eriksson, Anne Kiil-Berthelsen, Lise Borgwardt, Per Munck Af Rosenschöl. Use of PET/CT instead of CT-only when planning for radiation therapy does not notably increase life years lost in children being treated for cancer. Pediatric radiology. vol 45. issue 4. 2015-12-28. PMID:25378209. pet/ct may be more helpful than ct alone for radiation therapy planning, but the added risk due to higher doses of ionizing radiation is unknown. 2015-12-28 2023-08-13 Not clear
Daisuke Inoue, Tamon Kabata, Toru Maeda, Yoshitomo Kajino, Kenji Fujita, Kazuhiro Hasegawa, Takashi Yamamoto, Hiroyuki Tsuchiy. Value of computed tomography-based three-dimensional surgical preoperative planning software in total hip arthroplasty with developmental dysplasia of the hip. Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association. vol 20. issue 2. 2015-12-28. PMID:25623254. preoperative planning with computed tomography (ct)-based three-dimensional templating has been expanded to achieve more precise placement of hip components. 2015-12-28 2023-08-13 Not clear
Yolanda H Noorda, Lambertus W Bartels, Merel Huisman, Robbert J Nijenhuis, Maurice A A J van den Bosch, Josien P W Plui. Registration of CT to pre-treatment MRI for planning of MR-HIFU ablation treatment of painful bone metastases. Physics in medicine and biology. vol 59. issue 15. 2015-12-24. PMID:25004143. registration of ct to pre-treatment mri for planning of mr-hifu ablation treatment of painful bone metastases. 2015-12-24 2023-08-13 Not clear