All Relations between planning and ct

Publication Sentence Publish Date Extraction Date Species
Saba Pasha, Tom Schlösser, Xiaowei Zhu, Xochitl Mellor, René Castelein, John Flyn. Application of Low-dose Stereoradiography in In Vivo Vertebral Morphologic Measurements: Comparison With Computed Tomography. Journal of pediatric orthopedics. vol 39. issue 9. 2020-01-02. PMID:31503238. though computed tomography (ct) and 3 dimensional (3d) reconstruction of the spine and ribcage are powerful techniques for detailed monitoring of spinal growth and surgical planning of patients, drawbacks can arise. 2020-01-02 2023-08-13 Not clear
Kazuya Kobayashi, Satoru Wakasa, Koji Sato, Satoshi Kanai, Hiroaki Date, Satomi Kimura, Noriko Oyama-Manabe, Yoshiro Matsu. Quantitative analysis of regional endocardial geometry dynamics from 4D cardiac CT images: endocardial tracking based on the iterative closest point with an integrated scale estimation. Physics in medicine and biology. vol 64. issue 5. 2020-01-01. PMID:30669126. regional cardiac function analysis is important for the diagnosis and treatment planning of ischemic heart disease, but has not been sufficiently developed in the field of computed tomography (ct). 2020-01-01 2023-08-13 human
A K Bartella, M Kamal, I Scholl, S Schiffer, J Steegmann, D Ketelsen, F Hölzle, B Lethau. Virtual reality in preoperative imaging in maxillofacial surgery: implementation of "the next level"? The British journal of oral & maxillofacial surgery. vol 57. issue 7. 2019-12-30. PMID:31204187. preoperative examination using vr glasses can aid better understanding and planning of the surgical site in the future, and is an innovative piece of advanced technology for displaying ct, cone-beam ct, and mri anatomical data. 2019-12-30 2023-08-13 Not clear
Victor E Chen, Erin F Gillespie, Ryan P Manger, Lauren A Skerritt, Josephine H Tran, James A Proudfoot, Michael V Sherer, John P Einck, Loren K Mell, Kevin L Moore, Catheryn M Yasha. The impact of daily bladder filling on small bowel dose for intensity modulated radiation therapy for cervical cancer. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 44. issue 2. 2019-12-27. PMID:29573921. we identified 29 patients treated with imrt from 2010 to 2013 who underwent 2 planning computed tomography (ct) scans, 1 with a full bladder followed by 1 with an empty bladder. 2019-12-27 2023-08-13 Not clear
Victor E Chen, Erin F Gillespie, Ryan P Manger, Lauren A Skerritt, Josephine H Tran, James A Proudfoot, Michael V Sherer, John P Einck, Loren K Mell, Kevin L Moore, Catheryn M Yasha. The impact of daily bladder filling on small bowel dose for intensity modulated radiation therapy for cervical cancer. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 44. issue 2. 2019-12-27. PMID:29573921. to estimate dose to small bowel, radiation plans were created on both empty and full bladder ct scans using an automated knowledge-based planning modeling program. 2019-12-27 2023-08-13 Not clear
Vickie C Kong, Amy Taylor, Peter Chung, Tim Craig, Tara Rosewal. Comparison of 3 image-guided adaptive strategies for bladder locoregional radiotherapy. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 44. issue 2. 2019-12-27. PMID:29655582. daily dose was computed on all cone beam computed tomographies (cbcts) and deformed back to the planning computed tomography (ct) for dose summation afterward. 2019-12-27 2023-08-13 Not clear
Gijs J van der Veen, Tomas Janssen, Amber Duijn, Simon van Kranen, Rob J de Graaf, Geert Wortel, Terry G Wiersma, Eugène Dame. A robust volumetric arc therapy planning approach for breast cancer involving the axillary nodes. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 44. issue 2. 2019-12-27. PMID:30135024. to account for anatomical variation, planning was carried out on a computed tomography (ct) with an expanded breast, followed by segment weight optimization (swo) on the original planning ct (vmat + swo). 2019-12-27 2023-08-13 Not clear
Martin G Wagner, J Louis Hinshaw, Yinsheng Li, Timothy P Szczykutowicz, Paul Laeseke, Charles A Mistretta, Fred T Le. Ultra-Low Radiation Dose CT Fluoroscopy for Percutaneous Interventions: A Porcine Feasibility Study. Radiology. vol 291. issue 1. 2019-12-23. PMID:30644808. compared with ct fluoroscopy, the estimated dose for a percutaneous procedure, including planning acquisitions, was 0.99 msv (21% reduction) for patients (effective dose) and 0.015 µgy (97% reduction) for physicians (scattered dose in air). 2019-12-23 2023-08-13 Not clear
Rens van Haveren, Ben J M Heijmen, Sebastiaan Breedvel. Automatically configuring the reference point method for automated multi-objective treatment planning. Physics in medicine and biology. vol 64. issue 3. 2019-12-18. PMID:30566906. planning ct scans of 287 previously treated patients were included in a database, together with corresponding pareto optimal plans generated using our clinically applied two-phase [formula: see text]-constraint method (part of erasmus-icycle) for automated multi-objective treatment planning. 2019-12-18 2023-08-13 Not clear
Minoru Nakao, Shuichi Ozawa, Katsunori Yogo, Hideharu Miura, Kiyoshi Yamada, Fumika Hosono, Masahiro Hayata, Kentaro Miki, Takeo Nakashima, Yusuke Ochi, Daisuke Kawahara, Yoshiharu Morimoto, Toru Yoshizaki, Hiroshige Nozaki, Kosaku Habara, Yasushi Nagat. Tolerance levels of mass density for CT number calibration in photon radiation therapy. Journal of applied clinical medical physics. vol 20. issue 6. 2019-12-18. PMID:31081175. generally, there are two ct number calibration methods for commercial radiotherapy treatment planning system (rtps), namely ct number-relative electron density calibration (ct-red calibration) and ct number-mass density calibration (ct-md calibration). 2019-12-18 2023-08-13 Not clear
Zhixin Yao, Hansheng Feng, Yuntao Song, Shi Li, Yang Yang, Lingling Liu, Chunbo Li. A supervised network for fast image-guided radiotherapy (IGRT) registration. Journal of medical systems. vol 43. issue 7. 2019-12-18. PMID:31114956. 3d/3d image registration in igrt, which aligns planning computed tomography (ct) image set with on board cone beam ct (cbct) image set in a short time with high accuracy, is still a challenge due to its high computational cost and complex anatomical structure of medical image. 2019-12-18 2023-08-13 Not clear
Hideki Otsuk. Clinical Imaging Technology and the Diagnosis in Patient-centered Interdisciplinary Care. The journal of medical investigation : JMI. vol 66. issue 1.2. 2019-12-16. PMID:31064949. three-dimensional ct, such as virtual colonography and bronchography, isuseful for planning the approach before surgery or endoscopic study. 2019-12-16 2023-08-13 Not clear
J Kraeima, B Dorgelo, H A Gulbitti, R J H M Steenbakkers, K P Schepman, J L N Roodenburg, F K L Spijkervet, R H Schepers, M J H Witje. Multi-modality 3D mandibular resection planning in head and neck cancer using CT and MRI data fusion: A clinical series. Oral oncology. vol 81. 2019-12-13. PMID:29884410. multi-modality 3d mandibular resection planning in head and neck cancer using ct and mri data fusion: a clinical series. 2019-12-13 2023-08-13 Not clear
Philipp Freislederer, Asmus von Münchow, Florian Kamp, Christian Heinz, Sabine Gerum, Stefanie Corradini, Matthias Söhn, Michael Reiner, Falk Roeder, Ralf Floca, Markus Alber, Claus Belka, Katia Parod. Comparison of planned dose on different CT image sets to four-dimensional Monte Carlo dose recalculation using the patient's actual breathing trace for lung stereotactic body radiation therapy. Medical physics. vol 46. issue 7. 2019-12-12. PMID:31074510. we investigated this workflow on multiple computed tomography (ct) datasets in a clinical environment for stereotactic body radiation therapy (sbrt) treatment planning. 2019-12-12 2023-08-13 Not clear
Yuki Wada, Akira Anbai, Satoshi Kumagai, Eriko Okuyama, Kento Hatakeyama, Noriko Takagi, Manabu Hashimot. Effect of the types of pretreatment imaging modalities on the treatment response to palliative radiation for painful bone metastases from solid cancer: a single-center retrospective analysis. Radiation oncology (London, England). vol 14. issue 1. 2019-12-12. PMID:31174548. while irradiation planning is commonly performed using simulation computed tomography (ct), magnetic resonance imaging (mri), bone scintigraphy, and 2019-12-12 2023-08-13 Not clear
Carolina Sbordone, Paolo Toti, Bruno Brevi, Ranieri Martuscelli, Ludovico Sbordone, Federica Di Spirit. Computed tomography-aided descriptive analysis of maxillary and mandibular atrophies. Journal of stomatology, oral and maxillofacial surgery. vol 120. issue 2. 2019-12-11. PMID:30562623. the aim of the present retrospective chart review was to analyze by computed tomography (ct) scan technique the degree of maxillomandibular atrophies, searching for differences between totally- and partially-edentulous subjects, and possibly identify and classify maxillomandibular atrophy staged patterns for implant planning in both totally- and partially- edentulous jaws. 2019-12-11 2023-08-13 human
Guenther C Feigl, Firas Thaher, Sören Danz, Marcos Tatagiba, Anne K Hickmann, Antje Fahrig, Tomaz Velnar, Marcel Kullman. Feasibility and accuracy of a voxel-based neuronavigation system with 3D image rendering in preoperative planning and as a learning tool for young neurosurgeons, exemplified by the anatomical localization of the superior sagittal sinus. Bosnian journal of basic medical sciences. vol 19. issue 2. 2019-12-09. PMID:30684951. the study included 30 adult patients (18 female/12 male) who underwent a cranial computed tomography (ct) scan combined with venous angiography, for preoperative planning. 2019-12-09 2023-08-13 Not clear
J E Johnson, C Beltran, H Wan Chan Tseung, D W Mundy, J J Kruse, T J Whitaker, M G Herman, K M Furutan. Highly efficient and sensitive patient-specific quality assurance for spot-scanned proton therapy. PloS one. vol 14. issue 2. 2019-12-06. PMID:30763390. a monte carlo dose calculation engine, which was developed in-house, recalculates a planned dose distribution on the patient ct data set to verify the dose distribution represented by the treatment planning system. 2019-12-06 2023-08-13 Not clear
Mohsen Hasani, Bagher Farhood, Mahdi Ghorbani, Hamideh Naderi, Sepideh Saadatmand, Saeed Karimkhani Zandi, Courtney Knau. Effect of computed tomography number-relative electron density conversion curve on the calculation of radiotherapy dose and evaluation of Monaco radiotherapy treatment planning system. Australasian physical & engineering sciences in medicine. vol 42. issue 2. 2019-12-06. PMID:30848440. the accuracy of a computed tomography (ct)-relative electron density (red) curve may have an indirect impact on the accuracy of dose calculation by a treatment planning system (tps). 2019-12-06 2023-08-13 Not clear
Robert C Marchand, Nipun Sodhi, Manoshi Bhowmik-Stoker, Laura Scholl, Caitlin Condrey, Anton Khlopas, Assem A Sultan, Jared M Newman, Michael A Mon. Does the Robotic Arm and Preoperative CT Planning Help with 3D Intraoperative Total Knee Arthroplasty Planning? The journal of knee surgery. vol 32. issue 8. 2019-12-03. PMID:30112739. does the robotic arm and preoperative ct planning help with 3d intraoperative total knee arthroplasty planning? 2019-12-03 2023-08-13 Not clear