All Relations between planning and arc

Publication Sentence Publish Date Extraction Date Species
Stephen Bhagroo, Samuel B French, Joshua A Mathews, Daryl P Nazaret. Secondary monitor unit calculations for VMAT using parallelized Monte Carlo simulations. Journal of applied clinical medical physics. vol 20. issue 6. 2019-12-18. PMID:31127699. we have developed a fast and accurate in-house monte carlo (mc) secondary monitor unit (mu) check method, based on the egsnrc system, for independent verification of volumetric modulated arc therapy (vmat) treatment planning system dose calculations, in accordance with tg-114 recommendations. 2019-12-18 2023-08-13 Not clear
Jan Hofmaier, Raphael Bodensohn, Sylvia Garny, Indrawati Hadi, Daniel F Fleischmann, Michael Eder, Yavuz Dinc, Michael Reiner, Stefanie Corradini, Katia Parodi, Claus Belka, Maximilian Niyaz. Single isocenter stereotactic radiosurgery for patients with multiple brain metastases: dosimetric comparison of VMAT and a dedicated DCAT planning tool. Radiation oncology (London, England). vol 14. issue 1. 2019-12-12. PMID:31186023. in this dosimetric study, a dedicated planning tool for single isocenter stereotactic radiosurgery for multiple brain metastases using dynamic conformal arc therapy (dcat) was compared to standard volumetric modulated arc therapy (vmat). 2019-12-12 2023-08-13 Not clear
Emma Dyce, Dean Cutajar, Peter Metcalfe, Simon Downe. Dose verification for liver target volumes undergoing respiratory motion. Australasian physical & engineering sciences in medicine. vol 42. issue 2. 2019-12-06. PMID:31049839. plans were calculated using an elekta monaco treatment planning system (tps) on exhale phase study sets for conformal, volume modulated arc therapy (vmat) and intensity modulated radiation therapy (imrt) techniques, with breathing rates of 8, 14 and 23 bpm. 2019-12-06 2023-08-13 Not clear
Megumi Uto, Kengo Ogura, Nobutaka Mukumoto, Yuki Miyabe, Mitsuhiro Nakamura, Hideaki Hirashima, Tomohiro Katagiri, Keiichi Takehana, Masahiro Hiraoka, Takashi Mizowak. Single-isocenter volumetric-modulated Dynamic WaveArc therapy for two brain metastases. Japanese journal of radiology. vol 37. issue 8. 2019-12-02. PMID:31230185. this planning study compared the dose distribution and treatment time between single-isocenter volumetric-modulated arc therapy (vmat) with multiple straight non-coplanar arcs and single-isocenter vmdwat in patients with two brain metastases. 2019-12-02 2023-08-13 Not clear
Yongsook C Lee, Yongbok Ki. Circular collimator arc versus dynamic conformal arc treatment planning for linac-based stereotactic radiosurgery of an intracranial small single lesion: a perspective of lesion asymmetry. Radiation oncology (London, England). vol 14. issue 1. 2019-11-26. PMID:31159835. circular collimator arc versus dynamic conformal arc treatment planning for linac-based stereotactic radiosurgery of an intracranial small single lesion: a perspective of lesion asymmetry. 2019-11-26 2023-08-13 Not clear
Sergiu Scobioala, Christopher Kittel, Nicolas Wissmann, Uwe Haverkamp, Mohammed Channaoui, Omar Habibeh, Khaled Elsayad, Hans Theodor Eic. A treatment planning study comparing tomotherapy, volumetric modulated arc therapy, Sliding Window and proton therapy for low-risk prostate carcinoma. Radiation oncology (London, England). vol 11. issue 1. 2019-11-20. PMID:27671348. a treatment planning study comparing tomotherapy, volumetric modulated arc therapy, sliding window and proton therapy for low-risk prostate carcinoma. 2019-11-20 2023-08-13 Not clear
Sang Won Kang, Jin Beom Chung, Jae Sung Kim, In Ah Kim, Keun Yong Eom, Changhoon Song, Jeong Woo Lee, Jin Young Kim, Tae Suk Su. Optimal planning strategy among various arc arrangements for prostate stereotactic body radiotherapy with volumetric modulated arc therapy technique. Radiology and oncology. vol 51. issue 1. 2019-11-20. PMID:28265240. optimal planning strategy among various arc arrangements for prostate stereotactic body radiotherapy with volumetric modulated arc therapy technique. 2019-11-20 2023-08-13 Not clear
Y Wang, M Nielsen, M S MacPherso. Sci-Thur AM: Planning - 11: The impact of distributed calculation framework settings on plan calculation time. Medical physics. vol 39. issue 7Part2. 2019-11-20. PMID:28516528. some treatment planning system can divide a treatment plan calculation into multiple threads and allow both local and network computing resources to perform the calculation concurrently, which significantly reduces the calculation time for a calculation-demanding planning such as volumetric modulated arc therapy (vmat) or electron monte carlo (emc). 2019-11-20 2023-08-13 Not clear
G Zeng, J Murphy, S-L Annis, X Wu, Y Wang, T McGowan, M Macpherso. Poster - Thur Eve - 76: A quality control to achieve planning consistency in arc radiotherapy of the prostate. Medical physics. vol 39. issue 7Part4. 2019-11-20. PMID:28516642. poster - thur eve - 76: a quality control to achieve planning consistency in arc radiotherapy of the prostate. 2019-11-20 2023-08-13 Not clear
J Chow, R Jiang, D Marke. Poster - Thur Eve - 59: Dosimetric evaluation on the variation of PTV coverage due to patient size reduction using the prostate dose-volume factor in prostate radiotherapy. Medical physics. vol 39. issue 7Part3. 2019-11-20. PMID:28516710. we proposed to use the prostate dose-volume factor (pdvf), derived from the dose-volume dataset of planning target volume (ptv) in prostate radiotherapy to evaluate treatment plans of prostate volumetric modulated arc therapy (vmat) and intensity modulated radiotherapy (imrt). 2019-11-20 2023-08-13 Not clear
G Gilson, S Perkins, F Xia, C Coffey, G Din. SU-E-T-593: VMAT Vs. IMRT for Treatment of Neoplasms of the Brain: Dosimetric Quality and Delivery. Medical physics. vol 39. issue 6Part19. 2019-11-20. PMID:28517051. a retrospective study was performed to determine any dosimetric or delivery benefits for treatment planning with intensity-modulated radiotherapy (imrt) versus volumetric-modulated arc therapy (vmat) for the treatment of brain neoplasms. 2019-11-20 2023-08-13 Not clear
P Yan, D Horowiz, M Schweizer, C Cha. SU-E-T-564: Radiation Therapy for Lung Cancer: A Treatment Planning Comparison among Fixed Field IMRT, Coplanar and Noncoplanar Arcs Volumetric Modulated Arc Therapy. Medical physics. vol 39. issue 6Part19. 2019-11-20. PMID:28517052. su-e-t-564: radiation therapy for lung cancer: a treatment planning comparison among fixed field imrt, coplanar and noncoplanar arcs volumetric modulated arc therapy. 2019-11-20 2023-08-13 Not clear
T Sun, T Liu, Y Yi. SU-E-T-591: Volumetric-Modulated Arc Radiotherapy for Carcinomas of the Pituitary Adenomas: A Treatment Planning Comparison with Fixed Field IMRT. Medical physics. vol 39. issue 6Part19. 2019-11-20. PMID:28517077. su-e-t-591: volumetric-modulated arc radiotherapy for carcinomas of the pituitary adenomas: a treatment planning comparison with fixed field imrt. 2019-11-20 2023-08-13 Not clear
T Sun, T Liu, Y Yi. SU-E-T-591: Volumetric-Modulated Arc Radiotherapy for Carcinomas of the Pituitary Adenomas: A Treatment Planning Comparison with Fixed Field IMRT. Medical physics. vol 39. issue 6Part19. 2019-11-20. PMID:28517077. a treatment planning study was performed to compare volumetric-modulated arc radiotherapy against conventional fixed field imrt on pituitary adenomas cancer patients. 2019-11-20 2023-08-13 Not clear
E Schnell, T De La Fuente Herman, O Algan, L Syzek, T Herman, J Young, K Hildebrand, S Ahma. SU-E-T-577: Dosimetric Comparison of Volumetric Modulated Arc Therapy (VMAT), Step and Shoot and Sliding Window IMRT for Prostate Cancer. Medical physics. vol 39. issue 6Part19. 2019-11-20. PMID:28517085. this study aims to evaluate treatment plans generated by step- and-shoot (ss), sliding window (sw) and volumetric modulated arc therapy (vmat) in order to assess the differences in dose volume histograms of planning target volume (ptv) and organs at risk (oar), conformity indices, radiobiological evaluations, and plan quality for prostate cancer cases. 2019-11-20 2023-08-13 Not clear
G Yin, S Koren, M Lin, L Chen, C M. SU-E-T-594: Dosimetric Evaluation of Different Treatment Techniques for Prostate Cancer. Medical physics. vol 39. issue 6Part19. 2019-11-20. PMID:28517097. to evaluate the volumetric modulated arc therapy (vmat, rapidarc) and imrt plan quality for prostate deliveries conducted by two different treatment planning systems: oncentra masterplan (nucletron inc.) and eclipse (varian inc.). 2019-11-20 2023-08-13 Not clear
M Kunze-Busch, V Althof, P van Kollenburg, M Ten Brinke, J Woltman, R van der Maaze. SU-E-T-580: Does Arc Therapy Have the Potential to Improve Radiation Treatment of Hodgkin's Lymphoma Patients? Medical physics. vol 39. issue 6Part19. 2019-11-20. PMID:28517105. to evaluate whether arc therapy (helical tomotherapy and volumetric arc therapy; vmat) is superior to step and shoot imrt regarding sparing of lungs while maintaining adequate planning target volume (ptv) coverage in hodgkin's lymphoma patients . 2019-11-20 2023-08-13 Not clear
S Kim, C Serago, A Smit. SU-D-211-05: A Systematic Analysis of Penumbra Characteristics in Conformai Arc Delivery for SBRT and Its Utilization for Negative Margin Technique (NMT), a Novel Planning Strategy for Improving Dose Conformation. Medical physics. vol 39. issue 6Part3. 2019-11-20. PMID:28517401. su-d-211-05: a systematic analysis of penumbra characteristics in conformai arc delivery for sbrt and its utilization for negative margin technique (nmt), a novel planning strategy for improving dose conformation. 2019-11-20 2023-08-13 Not clear
T Neicu, P Chan, V Valakh, M Bizhan, C Miyamoto, S L. SU-E-T-648: Comparison of VMAT Vs Arc Treatment Plans for Patients Undergoing SBRT of Early-Stage Non-Small Cell Lung Cancer (NSCLC). Medical physics. vol 39. issue 6Part20. 2019-11-20. PMID:28517505. to evaluate the dosimetric implications of using vmat (volume modulated arc therapy) treatment planning techniques compared to traditional arc therapy methods for patients undergoing sbrt (stereotactic body radiation therapy) for early-stage non-small cell lung cancer (nsclc). 2019-11-20 2023-08-13 Not clear
J Chow, R Jian. SU-E-T-521: Dosimetric Effect on Variation of Patient Size in Prostate Volumetric Modulated Arc Therapy. Medical physics. vol 39. issue 6Part18. 2019-11-20. PMID:28518480. to evaluate dosimetric variations of planning target volume (ptv) on critical organs such as rectal wall, bladder and femoral head, when the patient size changes due to weight loss in prostate volumetric modulated arc therapy (vmat). 2019-11-20 2023-08-13 Not clear