All Relations between planning and arc

Publication Sentence Publish Date Extraction Date Species
Priyanka Agarwal, Rajesh Kinhika. In regard to the article 'Effectiveness of robust optimization in volumetric modulation arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique,' Vol. 61, No. 4, 2020. Journal of radiation research. vol 62. issue 4. 2021-07-13. PMID:34156471. in regard to the article 'effectiveness of robust optimization in volumetric modulation arc therapy using 6 and 10 mv flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique,' vol. 2021-07-13 2023-08-13 Not clear
Yoshinori Tanabe, Takayuki Ishida, Hidetoshi Eto, Tatsuhiro Sera, Yuki Emot. Optimizing planning CT using past CT images for prostate cancer volumetric modulated arc therapy. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 45. issue 3. 2021-07-12. PMID:32008885. optimizing planning ct using past ct images for prostate cancer volumetric modulated arc therapy. 2021-07-12 2023-08-13 Not clear
Yoshinori Tanabe, Takayuki Ishida, Hidetoshi Eto, Tatsuhiro Sera, Yuki Emot. Optimizing planning CT using past CT images for prostate cancer volumetric modulated arc therapy. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 45. issue 3. 2021-07-12. PMID:32008885. thirty-two patients undergoing volumetric modulated arc therapy for prostate cancer were evaluated for a 3d displacement error between bone- and prostate-matching spatial coordinates using multiple acquisition planning ct (mpct) scans. 2021-07-12 2023-08-13 Not clear
Jeanette Keil, Joanne Carda, Jade Reihart, Marjorie Seidel, Nishele Lenards, Ashley Hunzeke. A dosimetric study using split x-jaw planning technique for the treatment of endometrial carcinoma. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. vol 45. issue 3. 2021-07-12. PMID:32253081. the split x-jaw planning technique should be used with varian linear accelerators to produce superior volumetric modulated arc radiotherapy plans for planning target volumes larger than the maximum extent of the multileaf collimator in the x-jaw direction. 2021-07-12 2023-08-13 Not clear
Hideharu Miura, Shuichi Ozawa, Yoshiko Doi, Minoru Nakao, Katsumaro Kubo, Masahiko Kenjo, Yasushi Nagat. Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique. Journal of radiation research. vol 61. issue 4. 2021-07-08. PMID:32367109. effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 mv flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique. 2021-07-08 2023-08-13 Not clear
A G Livingstone, S B Crowe, S Sylvander, T Kair. Clinical implementation of a Monte Carlo based independent TPS dose checking system. Physical and engineering sciences in medicine. vol 43. issue 3. 2021-07-06. PMID:32780274. the increase in complexity of treatment plans over time through modalities such as intensity modulated radiotherapy (imrt) and volumetric modulated arc therapy (vmat) has often not been met with an increase in capability of the secondary dose calculation checking systems typically used to verify the treatment planning system. 2021-07-06 2023-08-13 Not clear
Maud Jaccard, Giorgio Lamanna, Melpomeni Kountouri, Michel Rouzaud, Raymond Miralbell, Thomas Zill. Dose-escalated volumetric modulated arc therapy for total marrow irradiation: A feasibility dosimetric study with 4DCT planning and simultaneous integrated boost. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 78. 2021-06-24. PMID:33002733. dose-escalated volumetric modulated arc therapy for total marrow irradiation: a feasibility dosimetric study with 4dct planning and simultaneous integrated boost. 2021-06-24 2023-08-13 Not clear
Maud Jaccard, Giorgio Lamanna, Melpomeni Kountouri, Michel Rouzaud, Raymond Miralbell, Thomas Zill. Dose-escalated volumetric modulated arc therapy for total marrow irradiation: A feasibility dosimetric study with 4DCT planning and simultaneous integrated boost. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 78. 2021-06-24. PMID:33002733. to evaluate the planning feasibility of dose-escalated total marrow irradiation (tmi) with simultaneous integrated boost (sib) to the active bone marrow (abm) using volumetric modulated arc therapy (vmat), and to assess the impact of using planning organs at risk (oar) volumes (prv) accounting for breathing motion in the optimization. 2021-06-24 2023-08-13 Not clear
Kentaro Miki, Martijn Kusters, Takeo Nakashima, Akito Saito, Daisuke Kawahara, Ikuno Nishibuchi, Tomoki Kimura, Yuji Murakami, Yasushi Nagat. Evaluation of optimization workflow using custom-made planning through predicted dose distribution for head and neck tumor treatment. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 80. 2021-06-24. PMID:33189047. lack of a reference dose distribution is one of the challenges in the treatment planning used in volumetric modulated arc therapy because numerous manual processes result from variations in the location and size of a tumor in different cases. 2021-06-24 2023-08-13 Not clear
Christian Harrer, Wolfgang Ullrich, Jan J Wilken. Prediction of multi-criteria optimization (MCO) parameter efficiency in volumetric modulated arc therapy (VMAT) treatment planning using machine learning (ML). Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 81. 2021-06-24. PMID:33445122. prediction of multi-criteria optimization (mco) parameter efficiency in volumetric modulated arc therapy (vmat) treatment planning using machine learning (ml). 2021-06-24 2023-08-13 Not clear
David J Sher, Andrew Godley, Yang Park, Colin Carpenter, Marc Nash, Hasti Hesami, Xinran Zhong, Mu-Han Li. Prospective study of artificial intelligence-based decision support to improve head and neck radiotherapy plan quality. Clinical and translational radiation oncology. vol 29. 2021-06-24. PMID:34159264. volumetric modulated arc therapy (vmat) planning for head and neck cancer is a complex process. 2021-06-24 2023-08-13 Not clear
Emilie Costa, Thomas Richir, Magalie Robilliard, Christel Bragard, Christelle Logerot, Youlia Kirova, Alain Fourquet, Ludovic De Marz. Assessment of a conventional volumetric-modulated arc therapy knowledge-based planning model applied to the new Halcyon© O-ring linac in locoregional breast cancer radiotherapy. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 86. 2021-06-22. PMID:34051551. assessment of a conventional volumetric-modulated arc therapy knowledge-based planning model applied to the new halcyon© o-ring linac in locoregional breast cancer radiotherapy. 2021-06-22 2023-08-13 Not clear
Emilie Costa, Thomas Richir, Magalie Robilliard, Christel Bragard, Christelle Logerot, Youlia Kirova, Alain Fourquet, Ludovic De Marz. Assessment of a conventional volumetric-modulated arc therapy knowledge-based planning model applied to the new Halcyon© O-ring linac in locoregional breast cancer radiotherapy. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 86. 2021-06-22. PMID:34051551. the aim of this study was to evaluate the performance of a knowledge-based planning (kbp) model for breast cancer trained on plans performed on a conventional linac with 6 mv ff (flattening filter) beams and volumetric-modulated arc therapy (vmat) for plans performed on the new jawless halcyon© system with 6 mv fff (flattening filter-free) beams. 2021-06-22 2023-08-13 Not clear
Damodar Pokhrel, Justin Visak, Lana Sanfor. A novel and clinically useful dynamic conformal arc (DCA)-based VMAT planning technique for lung SBRT. Journal of applied clinical medical physics. vol 21. issue 7. 2021-06-21. PMID:32306530. a novel and clinically useful dynamic conformal arc (dca)-based vmat planning technique for lung sbrt. 2021-06-21 2023-08-13 Not clear
Tomohiro Ono, Takamasa Mitsuyoshi, Takashi Shintani, Yusuke Tsuruta, Hiraku Iramina, Hideaki Hirashima, Yuki Miyabe, Mitsuhiro Nakamura, Yukinori Matsuo, Takashi Mizowak. Independent calculation-based verification of volumetric-modulated arc therapy-stereotactic body radiotherapy plans for lung cancer. Journal of applied clinical medical physics. vol 21. issue 7. 2021-06-21. PMID:32391645. this study aimed to investigate the feasibility of independent calculation-based verification of volumetric-modulated arc therapy (vmat)-stereotactic body radiotherapy (sbrt) for patients with lung cancer using a secondary treatment planning system (stps). 2021-06-21 2023-08-13 Not clear
LiCheng Kuo, PengPeng Zhang, Hai Pham, Åse M Ballangru. Implementation and validation of an in-house geometry optimization software for SRS VMAT planning of multiple cranial metastases. Journal of applied clinical medical physics. vol 21. issue 9. 2021-06-21. PMID:32627925. the go script provides optimal lesion clustering, isocenter placement, and collimator angle of each arc for cranial multi-lesion stereotactic radiosurgery (srs) volumetric modulated arc therapy (vmat) planning. 2021-06-21 2023-08-13 Not clear
Noriko Kishi, Mitsuhiro Nakamura, Hideaki Hirashima, Nobutaka Mukumoto, Keiichi Takehana, Megumi Uto, Yukinori Matsuo, Takashi Mizowak. Validation of the clinical applicability of knowledge-based planning models in single-isocenter volumetric-modulated arc therapy for multiple brain metastases. Journal of applied clinical medical physics. vol 21. issue 10. 2021-06-21. PMID:32951337. validation of the clinical applicability of knowledge-based planning models in single-isocenter volumetric-modulated arc therapy for multiple brain metastases. 2021-06-21 2023-08-13 Not clear
Noriko Kishi, Mitsuhiro Nakamura, Hideaki Hirashima, Nobutaka Mukumoto, Keiichi Takehana, Megumi Uto, Yukinori Matsuo, Takashi Mizowak. Validation of the clinical applicability of knowledge-based planning models in single-isocenter volumetric-modulated arc therapy for multiple brain metastases. Journal of applied clinical medical physics. vol 21. issue 10. 2021-06-21. PMID:32951337. to validate the clinical applicability of knowledge-based (kb) planning in single-isocenter volumetric-modulated arc therapy (vmat) for multiple brain metastases using the k-fold cross-validation (cv) method. 2021-06-21 2023-08-13 Not clear
Ce Han, Jinling Yi, Kecheng Zhu, Yongqiang Zhou, Yao Ai, Xiaomin Zheng, Congying Xie, Xiance Ji. Cross verification of independent dose recalculation, log files based, and phantom measurement-based pretreatment quality assurance for volumetric modulated arc therapy. Journal of applied clinical medical physics. vol 21. issue 11. 2021-06-21. PMID:33001540. independent treatment planning system (tps) check with mobius3d software, log files based quality assurance (qa) with mobiusfx, and phantom measurement-based qa with arccheck were performed and cross verified for head-and-neck (17 patients), chest (16 patients), and abdominal (19 patients) cancer patients who underwent volumetric modulated arc therapy (vmat). 2021-06-21 2023-08-13 Not clear
Savino Cilla, Anna Ianiro, Carmela Romano, Francesco Deodato, Gabriella Macchia, Pietro Viola, Milly Buwenge, Silvia Cammelli, Antonio Pierro, Vincenzo Valentini, Alessio G Morgant. Automated treatment planning as a dose escalation strategy for stereotactic radiation therapy in pancreatic cancer. Journal of applied clinical medical physics. vol 21. issue 11. 2021-06-21. PMID:33063456. to assess the feasibility of automated stereotactic volumetric modulated arc therapy (sbrt-vmat) planning using a simultaneous integrated boost (sib) approach as a dose escalation strategy for sbrt in pancreatic cancer. 2021-06-21 2023-08-13 Not clear