Fritz Thorey, Phillip Klages, Matthias Lerch, Thilo Floerkemeier, Henning Windhagen, Gabriela von Lewinsk. Cup positioning in primary total hip arthroplasty using an imageless navigation device: is there a learning curve? Orthopedics. vol 32. issue 10 Suppl. 2010-01-05. PMID:19835301. in this study, the success of cup positioning in total hip arthroplasty (tha) using an imageless navigation system was analyzed (1) during the learning period and (2) after the learning period for using the navigation system. 2010-01-05 2023-08-12 Not clear
Fritz Thorey, Phillip Klages, Matthias Lerch, Thilo Floerkemeier, Henning Windhagen, Gabriela von Lewinsk. Cup positioning in primary total hip arthroplasty using an imageless navigation device: is there a learning curve? Orthopedics. vol 32. issue 10 Suppl. 2010-01-05. PMID:19835301. imageless navigation is a dependable and accurate method of cup positioning during tha. 2010-01-05 2023-08-12 Not clear
Tobias Renkawitz, Markus Tingart, Joachim Grifka, Ernst Sendtner, Thomas Kaltei. Computer-assisted total hip arthroplasty: coding the next generation of navigation systems for orthopedic surgery. Expert review of medical devices. vol 6. issue 5. 2009-12-01. PMID:19751123. nonimage- or imageless-based navigation systems without the need for additional pre- or intra-operative image acquisition have stood the test to significantly reduce the variability in positioning the acetabular component and have shown precise measurement of leg length and offset changes during tha. 2009-12-01 2023-08-12 Not clear
Hirotsugu Ohashi, Masanori Matsuura, Yusaku Okamoto, Yoshiaki Okajim. Intra- and intersurgeon variability in image-free navigation system for THA. Clinical orthopaedics and related research. vol 467. issue 9. 2009-08-27. PMID:19381745. intra- and intersurgeon variability in image-free navigation system for tha. 2009-08-27 2023-08-12 Not clear
Takehito Hananouchi, Masaki Takao, Takashi Nishii, Hidenobu Miki, Daiki Iwana, Hideki Yoshikawa, Nobuhiko Sugan. Comparison of navigation accuracy in THA between the mini-anterior and -posterior approaches. The international journal of medical robotics + computer assisted surgery : MRCAS. vol 5. issue 1. 2009-04-29. PMID:19107818. comparison of navigation accuracy in tha between the mini-anterior and -posterior approaches. 2009-04-29 2023-08-12 Not clear
Olaf Hasart, Carsten Perka, Stephan Toht. Comparison between pointer-based and ultrasound-based navigation technique in THA using a minimally invasive approach. Orthopedics. vol 31. issue 10 Suppl 1. 2009-04-22. PMID:19298038. comparison between pointer-based and ultrasound-based navigation technique in tha using a minimally invasive approach. 2009-04-22 2023-08-12 Not clear
Sebastien Parratte, Mark W Pagnano, Krista Coleman-Wood, Kenton R Kaufman, Daniel J Berr. The 2008 Frank Stinchfield award: variation in postoperative pelvic tilt may confound the accuracy of hip navigation systems. Clinical orthopaedics and related research. vol 467. issue 1. 2009-01-16. PMID:18830796. most computer navigation systems used in total hip arthroplasty integrate preoperative pelvic tilt to calculate the anterior pelvic plane assuming tilt is constant; however, the consistency of pelvic tilt after tha has never been proven. 2009-01-16 2023-08-12 Not clear
Sebastien Parratte, Mark W Pagnano, Krista Coleman-Wood, Kenton R Kaufman, Daniel J Berr. The 2008 Frank Stinchfield award: variation in postoperative pelvic tilt may confound the accuracy of hip navigation systems. Clinical orthopaedics and related research. vol 467. issue 1. 2009-01-16. PMID:18830796. while navigation clearly improves the anatomical position of the component during tha, the functional position of the component will not always be improved because of the significant change between preoperative and postoperative pelvic tilt. 2009-01-16 2023-08-12 Not clear
Zhinian Wan, Aamer Malik, Branislav Jaramaz, Lisa Chao, Lawrence D Dor. Imaging and navigation measurement of acetabular component position in THA. Clinical orthopaedics and related research. vol 467. issue 1. 2009-01-16. PMID:18979147. imaging and navigation measurement of acetabular component position in tha. 2009-01-16 2023-08-12 Not clear
Paul J Duwelius, Lawrence D Dor. Minimally invasive total hip arthroplasty: an overview of the results. Instructional course lectures. vol 57. 2008-09-30. PMID:18399582. with time and technical advances such as computer navigation, the use of minimally invasive tha will become more prevalent. 2008-09-30 2023-08-12 Not clear
Timo M Ecker, Moritz Tannast, Stephen B Murph. Computed tomography-based surgical navigation for hip arthroplasty. Clinical orthopaedics and related research. vol 465. 2008-02-01. PMID:17876286. we reviewed 317 patients (344 hips) that underwent tha using computed tomography-based surgical navigation, including 112 thas using a simplified method of measuring leg length. 2008-02-01 2023-08-12 Not clear
Hidenobu Miki, Wataru Yamanashi, Takashi Nishii, Yoshinobu Sato, Hideki Yoshikawa, Nobuhiko Sugan. Anatomic hip range of motion after implantation during total hip arthroplasty as measured by a navigation system. The Journal of arthroplasty. vol 22. issue 7. 2008-01-31. PMID:17920464. using a navigation system, anatomical hip rom was accurately assessed after implantation during primary tha in 30 patients. 2008-01-31 2023-08-12 Not clear
Hartmuth Kiefer, Aneis Othma. Ultrasound vs pointer palpation based method in THA navigation: a comparative study. Orthopedics. vol 30. issue 10 Suppl. 2008-01-17. PMID:17983120. ultrasound vs pointer palpation based method in tha navigation: a comparative study. 2008-01-17 2023-08-12 Not clear
Hartmuth Kiefer, Aneis Othma. Ultrasound vs pointer palpation based method in THA navigation: a comparative study. Orthopedics. vol 30. issue 10 Suppl. 2008-01-17. PMID:17983120. intraoperative registration of the anterior pelvic plane is necessary for navigation during total hip arthroplasty (tha). 2008-01-17 2023-08-12 Not clear
Hartmuth Kiefer, Aneis Othma. Ultrasound vs pointer palpation based method in THA navigation: a comparative study. Orthopedics. vol 30. issue 10 Suppl. 2008-01-17. PMID:17983120. ultrasound referencing of bony landmarks was implemented in a tha navigation system (orthopilot, b. braun aesculap; tuttlingen, germany) as an alternative to pointer palpation. 2008-01-17 2023-08-12 Not clear
T M Ecker, S B Murph. Application of surgical navigation to total hip arthroplasty. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine. vol 221. issue 7. 2007-12-18. PMID:18019458. accomplishing these goals without compromising component positioning is the single greatest potential advantage to the application of surgical navigation to tha. 2007-12-18 2023-08-12 Not clear
T M Ecker, S B Murph. Application of surgical navigation to total hip arthroplasty. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine. vol 221. issue 7. 2007-12-18. PMID:18019458. the present paper describes the general principles of surgical navigation in tha with respect to methods of tracking, methods of registration, the role of image-free and image-based navigation, and methods of measuring leg-length change during surgery. 2007-12-18 2023-08-12 Not clear
T M Ecker, S B Murph. Application of surgical navigation to total hip arthroplasty. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine. vol 221. issue 7. 2007-12-18. PMID:18019458. further, a description is given of the clinical effect of combining surgical navigation with use of the superior capsulotomy technique of performing tha, which aims maximally to preserve the soft tissues surrounding the hip joint, allowing unrestricted progression of motion and weight-bearing following surgery. 2007-12-18 2023-08-12 Not clear
Sorin Blendea, Jocelyne Troccaz, Jean-Noel Ravey, Philippe Merlo. Image-free cup navigation inaccuracy: a two-study approach. Computer aided surgery : official journal of the International Society for Computer Aided Surgery. vol 12. issue 3. 2007-09-26. PMID:17538790. the present study tested the accuracy of an image-free navigation system used for total hip arthroplasty (tha). 2007-09-26 2023-08-12 Not clear
Christoph Eingartne. Current trends in total hip arthroplasty. Ortopedia, traumatologia, rehabilitacja. vol 9. issue 1. 2007-08-16. PMID:17514169. navigation technology has been introduced in tha to ensure perfect component positioning without outliers and concomitant risk of increased wear and implant failure. 2007-08-16 2023-08-12 Not clear