All Relations between navigation and cup

Publication Sentence Publish Date Extraction Date Species
Hiromasa Tanino, Yasuhiro Nishida, Ryo Mitsutake, Hiroshi It. Accuracy of a portable accelerometer-based navigation system for cup placement and intraoperative leg length measurement in total hip arthroplasty: a cross-sectional study. BMC musculoskeletal disorders. vol 22. issue 1. 2021-05-14. PMID:33757470. recently, a new version of a portable, accelerometer-based hip navigation system (new hipalign) was made available with a change in the method of measuring cup abduction and the addition of a leg length measurement function. 2021-05-14 2023-08-13 Not clear
Shunsaku Nishihara, Kenji Hayashid. Comparison between freehand technique and computed tomography-based navigation in acetabular cup placement through direct anterior approach for total hip arthroplasty. Archives of orthopaedic and trauma surgery. 2021-04-30. PMID:33929597. comparison between freehand technique and computed tomography-based navigation in acetabular cup placement through direct anterior approach for total hip arthroplasty. 2021-04-30 2023-08-13 Not clear
Shunsaku Nishihara, Kenji Hayashid. Comparison between freehand technique and computed tomography-based navigation in acetabular cup placement through direct anterior approach for total hip arthroplasty. Archives of orthopaedic and trauma surgery. 2021-04-30. PMID:33929597. the supine position during tha provides a more reproducible functional pelvic position than the lateral decubitus position and may allow freehand cup placement as reliable as that obtained by computer navigation. 2021-04-30 2023-08-13 Not clear
Shunsaku Nishihara, Kenji Hayashid. Comparison between freehand technique and computed tomography-based navigation in acetabular cup placement through direct anterior approach for total hip arthroplasty. Archives of orthopaedic and trauma surgery. 2021-04-30. PMID:33929597. the purpose of this study was to investigate the accuracy of freehand cup placement through a supine direct anterior approach (daa) compared with computed tomography (ct)-based navigation. 2021-04-30 2023-08-13 Not clear
Markus Weber, Matthias Meyer, Rüdiger von Eisenhart-Rothe, Tobias Renkawit. [The superiority of navigation and robotics in hip arthroplasty: fact or myth?] Der Orthopade. vol 50. issue 4. 2021-03-26. PMID:33666672. navigation and robotics enable increasing the precision of cup positioning, as well as successful biomechanical restoration of leg length and offset. 2021-03-26 2023-08-13 Not clear
Hartmuth Kiefer, Jannis Löchel, Keosun Sambo, Björn Leder, Georgi I Wassile. Anterior pelvic plane registration accuracy and cup position measurement using ultrasound- and pointer-based navigation in primary total hip arthroplasty. Technology and health care : official journal of the European Society for Engineering and Medicine. vol 28. issue 3. 2021-03-16. PMID:31658073. anterior pelvic plane registration accuracy and cup position measurement using ultrasound- and pointer-based navigation in primary total hip arthroplasty. 2021-03-16 2023-08-13 Not clear
Hartmuth Kiefer, Jannis Löchel, Keosun Sambo, Björn Leder, Georgi I Wassile. Anterior pelvic plane registration accuracy and cup position measurement using ultrasound- and pointer-based navigation in primary total hip arthroplasty. Technology and health care : official journal of the European Society for Engineering and Medicine. vol 28. issue 3. 2021-03-16. PMID:31658073. the use of navigation systems leads to more accurate cup positioning. 2021-03-16 2023-08-13 Not clear
Ryohei Takada, Tetsuya Jinno, Kazumasa Miyatake, Masanobu Hirao, Toshitaka Yoshii, Atsushi Okaw. Portable imageless navigation system and surgeon's estimate for accurate evaluation of acetabular cup orientation during total hip arthroplasty in supine position. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. vol 30. issue 4. 2021-02-22. PMID:31925538. portable imageless navigation system and surgeon's estimate for accurate evaluation of acetabular cup orientation during total hip arthroplasty in supine position. 2021-02-22 2023-08-13 Not clear
Hiroshi Asai, Yasuhiko Takegami, Taisuke Seki, Naoki Ishigur. Pelvic Tilt Reduces the Accuracy of Acetabular Component Placement When Using a Portable Navigation System: An In Vitro Study. Arthroplasty today. vol 7. 2021-02-10. PMID:33553546. while the margin of the error for the cup abduction and anteversion was larger than the values obtained from a computed tomography-based navigation system. 2021-02-10 2023-08-13 Not clear
Kazuma Takashima, Takashi Sakai, Shu Amano, Hidetoshi Hamada, Wataru Ando, Masaki Takao, Toshimitsu Hamasaki, Nobuo Nakamura, Nobuhiko Sugan. Does a computed tomography-based navigation system reduce the risk of dislocation after total hip arthroplasty in patients with osteonecrosis of the femoral head? A propensity score analysis. Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs. vol 23. issue 3. 2021-02-09. PMID:32072330. variance of cup inclination and anteversion angles was smaller in the navigation group than in the non-navigation group (p < 0.001). 2021-02-09 2023-08-13 Not clear
Tomonori Tetsunaga, Kazuki Yamada, Tomoko Tetsunaga, Tomoaki Sanki, Yoshi Kawamura, Toshifumi Ozak. An accelerometer-based navigation system provides acetabular cup orientation accuracy comparable to that of computed tomography-based navigation during total hip arthroplasty in the supine position. Journal of orthopaedic surgery and research. vol 15. issue 1. 2021-01-29. PMID:32295628. an accelerometer-based navigation system provides acetabular cup orientation accuracy comparable to that of computed tomography-based navigation during total hip arthroplasty in the supine position. 2021-01-29 2023-08-13 Not clear
Tomonori Tetsunaga, Kazuki Yamada, Tomoko Tetsunaga, Tomoaki Sanki, Yoshi Kawamura, Toshifumi Ozak. An accelerometer-based navigation system provides acetabular cup orientation accuracy comparable to that of computed tomography-based navigation during total hip arthroplasty in the supine position. Journal of orthopaedic surgery and research. vol 15. issue 1. 2021-01-29. PMID:32295628. this study compares the accuracy of cup orientation in tha using ct-based and accelerometer-based navigation systems. 2021-01-29 2023-08-13 Not clear
Shinya Hayashi, Shingo Hashimoto, Koji Takayama, Tomoyuki Matsumoto, Tomoyuki Kamenaga, Takaaki Fujishiro, Takafumi Hiranaka, Takahiro Niikura, Ryosuke Kurod. Evaluation of the accuracy of acetabular cup orientation using the accelerometer-based portable navigation system. Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association. vol 25. issue 4. 2020-12-31. PMID:31619323. evaluation of the accuracy of acetabular cup orientation using the accelerometer-based portable navigation system. 2020-12-31 2023-08-13 Not clear
Ahmed A Khalifa, Hatem M Bakr, Elsayed Said, Mohammad A Mahra. Technical Note on Using Intraoperative Smartphone Applications to Adjust Cup Inclination Angle during Total Hip Arthroplasty (THA). The archives of bone and joint surgery. vol 8. issue 6. 2020-12-16. PMID:33313356. cup placement can be improved using specific anatomical landmarks, computer navigation system and handheld navigation devices. 2020-12-16 2023-08-13 Not clear
Hiroyuki Ogawa, Kenji Kurosaka, Atsuko Sato, Naoyuki Hirasawa, Masaaki Matsubara, Sachiyuki Tsukad. Does An Augmented Reality-based Portable Navigation System Improve the Accuracy of Acetabular Component Orientation During THA? A Randomized Controlled Trial. Clinical orthopaedics and related research. vol 478. issue 5. 2020-11-24. PMID:31834164. we developed an augmented reality (ar)-based portable navigation system in which the surgeon can view the pelvic plane and placement angle of an acetabular cup on the display of a smartphone during tha. 2020-11-24 2023-08-13 Not clear
Tobias Renkawitz, Matthias Meyer, Florian Völlner, Markus Webe. [Intraoperative assessment of pelvic tilt and cup position in total hip arthroplasty: the relevance of navigation and robotics]. Der Orthopade. vol 49. issue 10. 2020-11-23. PMID:32909050. [intraoperative assessment of pelvic tilt and cup position in total hip arthroplasty: the relevance of navigation and robotics]. 2020-11-23 2023-08-13 Not clear
Hiromasa Tanino, Yasuhiro Nishida, Ryo Mitsutake, Hiroshi It. Portable Accelerometer-Based Navigation System for Cup Placement of Total Hip Arthroplasty: A Prospective, Randomized, Controlled Study. The Journal of arthroplasty. vol 35. issue 1. 2020-11-20. PMID:31563396. portable accelerometer-based navigation system for cup placement of total hip arthroplasty: a prospective, randomized, controlled study. 2020-11-20 2023-08-13 Not clear
Hiromasa Tanino, Yasuhiro Nishida, Ryo Mitsutake, Hiroshi It. Portable Accelerometer-Based Navigation System for Cup Placement of Total Hip Arthroplasty: A Prospective, Randomized, Controlled Study. The Journal of arthroplasty. vol 35. issue 1. 2020-11-20. PMID:31563396. the purpose of this study is to compare cup positioning with a portable, accelerometer-based hip navigation system and conventional surgical technique. 2020-11-20 2023-08-13 Not clear
Takuro Ueno, Tamon Kabata, Yoshitomo Kajino, Tomoharu Takagi, Takaaki Ohmori, Junya Yoshitani, Hiroyuki Tsuchiy. Influence of pelvic sagittal tilt on 3-dimensional bone coverage in total hip arthroplasty: a simulation analysis. Hip international : the journal of clinical and experimental research on hip pathology and therapy. vol 30. issue 3. 2020-10-19. PMID:31409140. in total hip arthroplasty with computer navigation assistance, cup orientation is generally determined according to the coordinate system relative to the functional pelvic plane (fpp). 2020-10-19 2023-08-13 Not clear
Hirokazu Takai, Tomoki Takahash. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system. Arthroplasty today. vol 3. issue 3. 2020-10-01. PMID:28913400. the upside-down cup-holding technique is useful and permits cemented cup users to utilize a navigation system for placement of the acetabular component. 2020-10-01 2023-08-13 Not clear