Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
Wenhua Chen, Yilin Yang, Wei Xing, Jianguo Qiu, Ya Pen. Sixteen-row multislice computed tomography angiography in the diagnosis and characterization of intracranial aneurysms: comparison with conventional angiography and intraoperative findings. Journal of neurosurgery. vol 108. issue 6. 2008-07-10. PMID:18518726. |
the goal of this study was to prospectively compare the effectiveness of 16-slice computed tomography (ct) angiography with that of conventional digital subtraction (ds) angiography and the surgical findings used to detect and characterize intracranial aneurysms. |
2008-07-10 |
2023-08-12 |
Not clear |
M Romijn, H A F Gratama van Andel, M A van Walderveen, M E Sprengers, J C van Rijn, W J van Rooij, H W Venema, C A Grimbergen, G J den Heeten, C B Majoi. Diagnostic accuracy of CT angiography with matched mask bone elimination for detection of intracranial aneurysms: comparison with digital subtraction angiography and 3D rotational angiography. AJNR. American journal of neuroradiology. vol 29. issue 1. 2008-04-28. PMID:17928381. |
diagnostic accuracy of ct angiography with matched mask bone elimination for detection of intracranial aneurysms: comparison with digital subtraction angiography and 3d rotational angiography. |
2008-04-28 |
2023-08-12 |
Not clear |
M Romijn, H A F Gratama van Andel, M A van Walderveen, M E Sprengers, J C van Rijn, W J van Rooij, H W Venema, C A Grimbergen, G J den Heeten, C B Majoi. Diagnostic accuracy of CT angiography with matched mask bone elimination for detection of intracranial aneurysms: comparison with digital subtraction angiography and 3D rotational angiography. AJNR. American journal of neuroradiology. vol 29. issue 1. 2008-04-28. PMID:17928381. |
our aim was to determine the diagnostic accuracy of multisection ct angiography combined with matched mask bone elimination (cta-mmbe) for detection of intracranial aneurysms compared with digital subtraction angiography (dsa) and 3d rotational angiography (3dra). |
2008-04-28 |
2023-08-12 |
Not clear |
H E Westerlaan, J Gravendeel, D Fiore, J D M Metzemaekers, R J M Groen, J J A Mooij, M Oudker. Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling. Neuroradiology. vol 49. issue 12. 2008-04-25. PMID:17891387. |
multislice ct angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling. |
2008-04-25 |
2023-08-12 |
Not clear |
H E Westerlaan, J Gravendeel, D Fiore, J D M Metzemaekers, R J M Groen, J J A Mooij, M Oudker. Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling. Neuroradiology. vol 49. issue 12. 2008-04-25. PMID:17891387. |
we sought to establish whether ct angiography (cta) can be applied to the planning and performance of clipping or coiling in ruptured intracranial aneurysms without recourse to intraarterial digital subtraction angiography (ia-dsa). |
2008-04-25 |
2023-08-12 |
Not clear |
A M McKinney, C S Palmer, C L Truwit, A Karagulle, M Teksa. Detection of aneurysms by 64-section multidetector CT angiography in patients acutely suspected of having an intracranial aneurysm and comparison with digital subtraction and 3D rotational angiography. AJNR. American journal of neuroradiology. vol 29. issue 3. 2008-04-23. PMID:18065510. |
detection of aneurysms by 64-section multidetector ct angiography in patients acutely suspected of having an intracranial aneurysm and comparison with digital subtraction and 3d rotational angiography. |
2008-04-23 |
2023-08-12 |
Not clear |
M van der Jagt, R J Bosman, I N van Schaik, I A C van der Bilt, L R Dekker, D F Zandstr. [Differential diagnosis in patients with suspected anoxic-ischaemic coma]. Nederlands tijdschrift voor geneeskunde. vol 152. issue 6. 2008-04-01. PMID:18326408. |
however, a coronary angiogram was normal and a ct of the brain revealed subarachnoid haemorrhage caused by a ruptured intracranial aneurysm. |
2008-04-01 |
2023-08-12 |
Not clear |
Alexander M McKinney, Charles L Truwit, Christopher S Palmer, Mehmet Teksa. Intracranial aneurysms: is the diagnostic accuracy rate of multidetector CT angiography equivalent to that of three-dimensional rotational conventional angiography? Radiology. vol 246. issue 3. 2008-03-25. PMID:18309022. |
intracranial aneurysms: is the diagnostic accuracy rate of multidetector ct angiography equivalent to that of three-dimensional rotational conventional angiography? |
2008-03-25 |
2023-08-12 |
Not clear |
C-A Taschner, L Thines, M Lernout, J-P Lejeune, X Lecler. Treatment decision in ruptured intracranial aneurysms: comparison between multi-detector row CT angiography and digital subtraction angiography. Journal of neuroradiology = Journal de neuroradiologie. vol 34. issue 4. 2008-02-05. PMID:17761283. |
treatment decision in ruptured intracranial aneurysms: comparison between multi-detector row ct angiography and digital subtraction angiography. |
2008-02-05 |
2023-08-12 |
Not clear |
G Richter, T Engelhorn, T Struffert, M Doelken, O Ganslandt, J Hornegger, W A Kalender, A Doerfle. Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms. AJNR. American journal of neuroradiology. vol 28. issue 10. 2008-02-05. PMID:17893214. |
the purpose of this work was to evaluate angiographic ct (act) in the combined application of a self-expanding neurovascular stent and detachable platinum coils in the management of broad-based and fusiform intracranial aneurysms. |
2008-02-05 |
2023-08-12 |
Not clear |
B Lubicz, M Levivier, O François, P Thoma, N Sadeghi, L Collignon, D Balériau. Sixty-four-row multisection CT angiography for detection and evaluation of ruptured intracranial aneurysms: interobserver and intertechnique reproducibility. AJNR. American journal of neuroradiology. vol 28. issue 10. 2008-02-05. PMID:17898200. |
sixty-four-row multisection ct angiography for detection and evaluation of ruptured intracranial aneurysms: interobserver and intertechnique reproducibility. |
2008-02-05 |
2023-08-12 |
Not clear |
B Lubicz, M Levivier, O François, P Thoma, N Sadeghi, L Collignon, D Balériau. Sixty-four-row multisection CT angiography for detection and evaluation of ruptured intracranial aneurysms: interobserver and intertechnique reproducibility. AJNR. American journal of neuroradiology. vol 28. issue 10. 2008-02-05. PMID:17898200. |
the purpose of this work was to assess intertechnique and interobserver reproducibility of 64-row multisection ct angiography (cta) used to detect and evaluate intracranial aneurysms. |
2008-02-05 |
2023-08-12 |
Not clear |
M Tryfonidis, A L Evans, S C Coley, T L Hodgson, D J A Connolly, C A J Romanowski, U J Pate. The value of radio-anatomical features on non-contrast CT scans in localizing the source in aneurysmal subarachnoid haemorrhage. Clinical anatomy (New York, N.Y.). vol 20. issue 6. 2007-12-19. PMID:17674417. |
this study was carried out to assess whether radioanatomical features on noncontrast enhanced computerised tomography (ct) scans may be of value in localizing ruptured intracranial aneurysms. |
2007-12-19 |
2023-08-12 |
Not clear |
Karsten Papke, Christiane K Kuhl, Martin Fruth, Cornel Haupt, Martin Schlunz-Hendann, Dieter Sauner, Martin Fiebich, Alan Bani, Friedhelm Brasse. Intracranial aneurysms: role of multidetector CT angiography in diagnosis and endovascular therapy planning. Radiology. vol 244. issue 2. 2007-09-12. PMID:17641372. |
intracranial aneurysms: role of multidetector ct angiography in diagnosis and endovascular therapy planning. |
2007-09-12 |
2023-08-12 |
Not clear |
Karsten Papke, Christiane K Kuhl, Martin Fruth, Cornel Haupt, Martin Schlunz-Hendann, Dieter Sauner, Martin Fiebich, Alan Bani, Friedhelm Brasse. Intracranial aneurysms: role of multidetector CT angiography in diagnosis and endovascular therapy planning. Radiology. vol 244. issue 2. 2007-09-12. PMID:17641372. |
to evaluate the sensitivity of 16-detector row computed tomographic (ct) angiography in diagnosis of intracranial aneurysms and to determine whether multidetector ct angiography provides sufficient diagnostic information to guide endovascular treatment, with combined imaging and clinical data as the reference standard. |
2007-09-12 |
2023-08-12 |
Not clear |
Jy Gauvrit, D Trystram, C Oppenheim, X Lecler. [Advanced vascular imaging techniques of supra-aortic, encephalic and medullary vessels]. Journal de radiologie. vol 88. issue 3 Pt 2. 2007-05-31. PMID:17457258. |
mri of the carotid plaques, ct angiography in the detection of the intracranial aneurysms, intracranial time-resolved mra and mra of the spinal cord took their place in the field of the noninvasive vascular imaging. |
2007-05-31 |
2023-08-12 |
Not clear |
D Kojo Hamilton, Neal F Kassell, Mary E Jensen, Aaron S Dumon. Subarachnoid hemorrhage and diffuse vasculopathy in an adult infected with HIV. Case report. Journal of neurosurgery. vol 106. issue 3. 2007-04-03. PMID:17367072. |
computed tomography (ct) scanning demonstrated diffuse subarachnoid hemorrhage (sah), and subsequent ct angiography revealed multiple large and giant intracranial aneurysms with diffuse vasculopathy. |
2007-04-03 |
2023-08-12 |
Not clear |
D Y Yoon, K J Lim, C S Choi, B M Cho, S M Oh, S K Chan. Detection and characterization of intracranial aneurysms with 16-channel multidetector row CT angiography: a prospective comparison of volume-rendered images and digital subtraction angiography. AJNR. American journal of neuroradiology. vol 28. issue 1. 2007-03-14. PMID:17213425. |
detection and characterization of intracranial aneurysms with 16-channel multidetector row ct angiography: a prospective comparison of volume-rendered images and digital subtraction angiography. |
2007-03-14 |
2023-08-12 |
Not clear |
D Y Yoon, K J Lim, C S Choi, B M Cho, S M Oh, S K Chan. Detection and characterization of intracranial aneurysms with 16-channel multidetector row CT angiography: a prospective comparison of volume-rendered images and digital subtraction angiography. AJNR. American journal of neuroradiology. vol 28. issue 1. 2007-03-14. PMID:17213425. |
the aim of our study was to compare multidetector row ct angiography (mdcta) with digital subtraction angiography (dsa) in the detection and characterization of intracranial aneurysms. |
2007-03-14 |
2023-08-12 |
Not clear |
A Ozturk, I Saatci, A G Pamuk, C Erdogan, I Akmangit, S Geyik, H S Cekirg. Focal increased cortical density in immediate postembolization CT scans of patients with intracranial aneurysms. AJNR. American journal of neuroradiology. vol 27. issue 9. 2007-01-12. PMID:17032858. |
focal increased cortical density in immediate postembolization ct scans of patients with intracranial aneurysms. |
2007-01-12 |
2023-08-12 |
Not clear |