All Relations between planning and tps

Publication Sentence Publish Date Extraction Date Species
L S Walker, J P Byrn. Clinical impact of DVH uncertainties. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2024-07-10. PMID:38987038. this work shows the design and implementation of methods for assessing the accuracy of dose and volume computations performed by treatment planning systems (tps), and other analytical tools. 2024-07-10 2024-07-13 Not clear
Peng Zhou, Yankui Chang, Shijun Li, Jia Luo, Lin Lei, Yufen Shang, Xi Pei, Qiang Ren, Chuan Che. Clinical application of a GPU-accelerated monte carlo dose verification for cyberknife M6 with Iris collimator. Radiation oncology (London, England). vol 19. issue 1. 2024-07-03. PMID:38956685. to apply an independent gpu-accelerated monte carlo (mc) dose verification for cyberknife m6 with iris collimator and evaluate the dose calculation accuracy of raytracing (tps-rt) algorithm and monte carlo (tps-mc) algorithm in the precision treatment planning system (tps). 2024-07-03 2024-07-06 Not clear
K Sanklaa, C Pitikiattikul, M Rittiwong, N Thiamthan, S Turathong, T Sanghangthu. Surface dose measurement by optically stimulated luminescent dosimeter: A phantom study. Radiography (London, England : 1995). 2024-07-02. PMID:38955646. the dose calculation from a treatment planning system (tps) might also be inaccurate. 2024-07-02 2024-07-06 Not clear
Peng Zhou, Jia Luo, Xiaona Su, Chuan Che. The effect of Inc parameter on VMAT radiotherapy plans quality for rectal cancer using Monaco TPS. Journal of applied clinical medical physics. 2024-06-26. PMID:38923699. to investigate the effect of the increment of gantry angle (inc) parameter setting of the monaco treatment planning system (monaco tps) on the dosimetry and quality parameters of the volumetric modulated arc therapy (vmat) program for rectal cancer. 2024-06-26 2024-06-29 Not clear
Kamonchanok Archawametheekul, Chanon Puttanawarut, Sithiphong Suphaphong, Chuleeporn Jiarpinitnun, Siwaporn Sakulsingharoj, Nauljun Stansook, Suphalak Khachonkha. The Investigating Image Registration Accuracy and Contour Propagation for Adaptive Radiotherapy Purposes in Line with the Task Group No. 132 Recommendation. Journal of medical physics. vol 49. issue 1. 2024-06-03. PMID:38828076. this study investigates the accuracy of the deformable image registration (dir) and contour propagation features of smartadapt, an application in the eclipse treatment planning system (tps) version 16.1. 2024-06-03 2024-06-05 Not clear
Yin Gao, Yang-Kyun Park, Xun Ji. Human-like intelligent automatic treatment planning of head and neck cancer radiation therapy. Physics in medicine and biology. 2024-05-14. PMID:38744304. we have proposed an intelligent automatic treatment planning framework with a virtual treatment planner (vtp), an artificial intelligence robot built using deep reinforcement learning (drl), autonomously operating a treatment planning system (tps). 2024-05-14 2024-05-27 human
Yin Gao, Yang-Kyun Park, Xun Ji. Human-like intelligent automatic treatment planning of head and neck cancer radiation therapy. Physics in medicine and biology. 2024-05-14. PMID:38744304. this study extends our previous successes in relatively simple prostate cancer rt planning to head-and-neck (h&n) cancer, a more challenging context even for human planners due to multiple prescription levels, proximity of targets to critical organs, and tight dosimetric constraints. we integrated vtp with a real clinical tps to establish a fully automated planning workflow guided by vtp. 2024-05-14 2024-05-27 human
Yin Gao, Yang-Kyun Park, Xun Ji. Human-like intelligent automatic treatment planning of head and neck cancer radiation therapy. Physics in medicine and biology. 2024-05-14. PMID:38744304. for clinical cases, vtp-generated plans achieved an average vtp score of 125.33±11.12, which outperformed the corresponding clinical plans with an average score of117.76±13.56. we successfully integrated vtp with the clinical tps to achieve a fully automated treatment planning workflow. 2024-05-14 2024-05-27 human
Georgios Alexiou, Georgia Malatara, Spyridon Papatheodorou, Christos Dimitroukas, Despina Spyropoulou, George Panayiotaki. Validation of the Elekta iBEAM Evo couchtop modeling in the Monaco treatment planning system. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2024-05-12. PMID:38735781. however, the presence of the couchtop needs proper modeling in the treatment planning system (tps) due to attenuation; otherwise, the tumor dose is reduced. 2024-05-12 2024-05-27 Not clear
Mengyu Jia, Zhaoqi Wei, Feng Gao, Mingfeng Jiang, Wei Wang, Zhiyong Yuan, Brian W Pogu. Time-gated single-pixel imaging of Cherenkov emission from a medical linear accelerator. Optics letters. vol 49. issue 9. 2024-05-01. PMID:38691735. the cherenkov image-based projection percent depth dose curves (ppdds) were compared to ppdds simulated by the treatment planning system (tps), with an overall average error of 0.48, 0.42, 0.65, and 1.08% for the 3, 5, 7, and 9 cm square beams, respectively. 2024-05-01 2024-05-04 Not clear
Noemi Giannini, Giovanni Gadducci, Taiusha Fuentes, Alessandra Gonnelli, Fabio Di Martino, Paola Puccini, Monica Naso, Francesco Pasqualetti, Simone Capaccioli, Fabiola Paia. Electron FLASH radiotherapy in vivo studies. A systematic review. Frontiers in oncology. vol 14. 2024-04-26. PMID:38655137. additionally, this linac totally lacks an integrated and dedicated treatment planning system (tps) able to evaluate the internal dose distribution in the case of in vivo experiments. 2024-04-26 2024-04-28 Not clear
Elizabeth Patterson, Marcus Powers, Peter E Metcalfe, Dean Cutajar, Bradley M Oborn, John A Baine. Electron streaming dose measurements and calculations on a 1.5 T MR-Linac. Journal of applied clinical medical physics. 2024-04-25. PMID:38661097. to evaluate the accuracy of different dosimeters and the treatment planning system (tps) for assessing the skin dose due to the electron streaming effect (ese) on a 1.5 t magnetic resonance (mr)-linac. 2024-04-25 2024-04-28 Not clear
Guido Mora, Miguel Martín-Landrov. Use of Zernike moments to characterize dose conformity for radiotherapy treatment plans. Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. vol 209. 2024-04-20. PMID:38642442. dose conformity is an essential parameter used in radiotherapy and radiosurgery that measures the correspondence of the dose distribution derived from a treatment planning system (tps) with the actual volume to be treated, the planning treatment volume (ptv). 2024-04-20 2024-04-23 Not clear
G Franciosini, D Carlotti, F Cattani, A De Gregorio, V De Liso, F De Rosa, M Di Francesco, F Di Martino, G Felici, J Harold Pensavalle, M C Leonardi, M Marafini, A Muscato, F Paiar, V Patera, P Poortmans, A Sciubba, A Schiavi, M Toppi, G Traini, A Trigilio, A Sart. IOeRT conventional and FLASH treatment planning system implementation exploiting fast GPU Monte Carlo: The case of breast cancer. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 121. 2024-04-12. PMID:38608421. one of the main limitations of this technique is the absence of a treatment planning system (tps) that could greatly help in ensuring a proper coverage of the target volume during irradiation. 2024-04-12 2024-04-15 Not clear
Takahiro Aoyama, Yutaro Koide, Hidetoshi Shimizu, Tomoki Kitagawa, Tohru Iwata, Shingo Hashimoto, Hiroyuki Tachibana, Takeshi Kodair. Trends and distribution of external radiation therapy facilities in Japan based on Survey of Medical Institutions from the Ministry of Health, Labour and Welfare. Journal of radiation research. 2024-04-11. PMID:38602048. data on the number of rt facilities, high-precision rt facilities, rt devices and treatment planning systems (tps) categorized by the number of beds and prefecture from 1996 to 2020 were analyzed. 2024-04-11 2024-04-13 Not clear
Hüseyin Doğu, Anas Abdalla. A novel guide device for pedicle screw insertion using three-dimensional preoperative planning in open lumbar spinal surgery: a comparative retrospective study. Neurological research. 2024-04-01. PMID:38557428. the use of preoperative planning can minimize the complications related to transpedicular screw (tps) misplacement. 2024-04-01 2024-04-04 Not clear
Paul Retif, Abdourahamane Djibo Sidikou, Alexandre Waltener, Romain Letellier, Anwar Al Salah, Estelle Pfletschinger, Fabian Taesch, Emilie Verrecchia-Ramos, Xavier Miche. Integrating cine EPID, dynamic delivery, and the off-axis Winston-Lutz test to enhance quality control in multiple brain metastasis stereotactic radiotherapy. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). vol 120. 2024-03-28. PMID:38547546. a two-step doawl is proposed: step 1 calculates local-field shifts using dynamic mlc movements in the beam-eye view data from the treatment planning system (tps), while step 2 processes cine epid images with an oawl algorithm to isolate true deviations. 2024-03-28 2024-03-31 Not clear
Zakaria Ait Elcadi, Mostafa El Moussaoui, Souha Aouadi, Renilmon Sukurmaran, Rabih Hammoud, Noora Al-Hammadi, Yassine Toufique, Othmane Bouhal. GATE Monte Carlo Approach to heterogeneity dose distribution in small fields used in radiation therapy. Biomedical physics & engineering express. 2024-03-22. PMID:38518360. the accurate dosage prediction in radiation therapy is challenging, prompting a need for precision beyond conventional clinical treatment planning systems (tps). 2024-03-22 2024-03-25 Not clear
Urszula Jelen, Claire Pagulayan, Zoë Moutrie, Jason Arts, Armia George, Michael G Jameso. Technical note: Cryostat transmission characterization for MR linac - temporal stability, clinical impact and change implementation. Medical physics. 2024-03-11. PMID:38465398. the resulting beam attenuation must be considered for output calibration and its variation with gantry angle must be characterized in the treatment planning system (tps). 2024-03-11 2024-03-14 Not clear
William S Ferris, Blake R Smith, Daniel E Hyer, Joel J St-Aubi. Technical note: A simple method for patient-specific quality assurance for lateral targets on a 1.5 T MR-Linac. Journal of applied clinical medical physics. 2024-03-01. PMID:38426612. computed tomography (ct) scans are used to simulate the setup and create a qa plan template in the monaco treatment planning system (tps). 2024-03-01 2024-03-03 Not clear