Publication |
Sentence |
Publish Date |
Extraction Date |
Species |
Masanori Okamoto, Yasuhiko Takegami, Yusuke Osawa, Shinya Tanaka, Tatsuya Nobori, Shiro Imagam. Accelerometer-based portable navigation system shows no superior accuracy over pelvic alignment guide for acetabular cup placement in total hip arthroplasty in lateral decubitus position. Archives of orthopaedic and trauma surgery. 2024-09-30. PMID:39347968. |
accelerometer-based portable navigation system shows no superior accuracy over pelvic alignment guide for acetabular cup placement in total hip arthroplasty in lateral decubitus position. |
2024-09-30 |
2024-10-02 |
Not clear |
Toshiki Konishi, Taishi Sato, Satoshi Hamai, Shinya Kawahara, Daisuke Hara, Yasuharu Nakashim. Robotic Arm-Assisted System Improved Accuracy of Cup Position and Orientation in Cementless Total Hip Arthroplasty for Dysplastic Hips: A Comparison Among Groups With Manual Placement, Computed Tomography-Based Navigation, and Robotic Surgery. Arthroplasty today. vol 28. 2024-08-05. PMID:39100425. |
robotic arm-assisted system improved accuracy of cup position and orientation in cementless total hip arthroplasty for dysplastic hips: a comparison among groups with manual placement, computed tomography-based navigation, and robotic surgery. |
2024-08-05 |
2024-08-07 |
Not clear |
Toshiki Konishi, Taishi Sato, Satoshi Hamai, Shinya Kawahara, Daisuke Hara, Yasuharu Nakashim. Robotic Arm-Assisted System Improved Accuracy of Cup Position and Orientation in Cementless Total Hip Arthroplasty for Dysplastic Hips: A Comparison Among Groups With Manual Placement, Computed Tomography-Based Navigation, and Robotic Surgery. Arthroplasty today. vol 28. 2024-08-05. PMID:39100425. |
this study aimed to compare the accuracy of cup placement position and orientation across robotic arm-assisted systems (r-tha), computed tomography-based navigation (n-tha), and manual procedure (m-tha) in tha for osteoarthritis secondary to dysplasia. |
2024-08-05 |
2024-08-07 |
Not clear |
Colin C Neitzke, Sonia K Chandi, Elizabeth B Gausden, Eytan M Debbi, Peter K Sculco, Brian P Chalmer. Use of Computer Navigation for Optimal Acetabular Cup Placement in Revision Total Hip Arthroplasty: Case Reports and Surgical Techniques. Arthroplasty today. vol 27. 2024-07-29. PMID:39071827. |
use of computer navigation for optimal acetabular cup placement in revision total hip arthroplasty: case reports and surgical techniques. |
2024-07-29 |
2024-08-02 |
Not clear |
Filippo Romanelli, Ian S Hong, Jibran A Khan, Andrew Porter, Jaclyn M Jankowski, Frank A Liporace, Richard S Yoo. Intraoperative Fluoroscopy Versus Navigation to Determine Cup Anteversion in Direct Anterior Total Hip Replacement: A Technical Trick for Obtaining "True" Anteversion. Arthroplasty today. vol 27. 2024-07-02. PMID:38952777. |
intraoperative fluoroscopy versus navigation to determine cup anteversion in direct anterior total hip replacement: a technical trick for obtaining "true" anteversion. |
2024-07-02 |
2024-07-04 |
Not clear |
Filippo Romanelli, Ian S Hong, Jibran A Khan, Andrew Porter, Jaclyn M Jankowski, Frank A Liporace, Richard S Yoo. Intraoperative Fluoroscopy Versus Navigation to Determine Cup Anteversion in Direct Anterior Total Hip Replacement: A Technical Trick for Obtaining "True" Anteversion. Arthroplasty today. vol 27. 2024-07-02. PMID:38952777. |
during acetabular cup positioning, intraoperative measurements of cup anteversion were taken using both fluoroscopy and navigation system. |
2024-07-02 |
2024-07-04 |
Not clear |
Filippo Romanelli, Ian S Hong, Jibran A Khan, Andrew Porter, Jaclyn M Jankowski, Frank A Liporace, Richard S Yoo. Intraoperative Fluoroscopy Versus Navigation to Determine Cup Anteversion in Direct Anterior Total Hip Replacement: A Technical Trick for Obtaining "True" Anteversion. Arthroplasty today. vol 27. 2024-07-02. PMID:38952777. |
the high degree of agreement between fluoroscopic and navigation measurement of acetabular cup anteversion supports the use of fluoroscopy in settings with limited access to navigation systems in direct anterior total hip arthroplasty. |
2024-07-02 |
2024-07-04 |
Not clear |
Junya Shimizu, Satoshi Nagoya, Ima Kosukegawa, Arata Kanaizumi, Naoya Nakahashi, Atsushi Teramot. The Accuracy of Cup Placement in Total Hip Arthroplasty (THA) Using an Augmented Reality-Based Navigation System. Cureus. vol 16. issue 4. 2024-06-03. PMID:38826595. |
the accuracy of cup placement in total hip arthroplasty (tha) using an augmented reality-based navigation system. |
2024-06-03 |
2024-06-05 |
Not clear |
Yohei Ohyama, Yukihide Minoda, Ryo Sugama, Sho Masuda, Yoichi Ohta, Hiroaki Nakamur. A novel imageless accelerometer-based navigation system improves acetabular cup placement accuracy during total hip arthroplasty in the lateral decubitus position. Archives of orthopaedic and trauma surgery. 2024-05-16. PMID:38753013. |
a novel imageless accelerometer-based navigation system improves acetabular cup placement accuracy during total hip arthroplasty in the lateral decubitus position. |
2024-05-16 |
2024-05-27 |
Not clear |
Yohei Ohyama, Yukihide Minoda, Ryo Sugama, Sho Masuda, Yoichi Ohta, Hiroaki Nakamur. A novel imageless accelerometer-based navigation system improves acetabular cup placement accuracy during total hip arthroplasty in the lateral decubitus position. Archives of orthopaedic and trauma surgery. 2024-05-16. PMID:38753013. |
the accuracy of acetabular cup placement using conventional portable imageless navigation systems in total hip arthroplasty (tha) in the lateral decubitus position remains challenging. |
2024-05-16 |
2024-05-27 |
Not clear |
Yohei Ohyama, Yukihide Minoda, Ryo Sugama, Sho Masuda, Yoichi Ohta, Hiroaki Nakamur. A novel imageless accelerometer-based navigation system improves acetabular cup placement accuracy during total hip arthroplasty in the lateral decubitus position. Archives of orthopaedic and trauma surgery. 2024-05-16. PMID:38753013. |
several novel portable imageless navigation systems have been developed recently to improve cup placement accuracy in tha. |
2024-05-16 |
2024-05-27 |
Not clear |
Yohei Ohyama, Yukihide Minoda, Ryo Sugama, Sho Masuda, Yoichi Ohta, Hiroaki Nakamur. A novel imageless accelerometer-based navigation system improves acetabular cup placement accuracy during total hip arthroplasty in the lateral decubitus position. Archives of orthopaedic and trauma surgery. 2024-05-16. PMID:38753013. |
this study compared the accuracy of acetabular cup placement using a conventional accelerometer-based portable navigation (c-apn) system and a novel accelerometer-based portable navigation (n-apn) system during tha in the lateral decubitus position. |
2024-05-16 |
2024-05-27 |
Not clear |
Androniki Drakou, Pavlos Altsitzioglou, Spyridon Sioutis, Anastasios G Roustemis, Dimitrios S Mastrokalos, Dimitrios Koulali. Optimizing Hip Replacement Procedure in Cerebral Palsy-Related Spastic Hip Dysplasia: A Case Report. Cureus. vol 16. issue 4. 2024-05-06. PMID:38707032. |
this study explores a method of intraoperative navigation to precisely execute preoperative strategies for spinopelvic alignment and optimal cup placement. |
2024-05-06 |
2024-05-08 |
Not clear |
Shinya Hayashi, Yuichi Kuroda, Naoki Nakano, Tomoyuki Matsumoto, Tomoyuki Kamenaga, Masanori Tsubosaka, Ryosuke Kurod. Accuracy of portable navigation during THA in patients with severe developmental dysplasia of hip. Archives of orthopaedic and trauma surgery. 2024-04-25. PMID:38661997. |
this study aimed to analyze the orientation accuracy of cup insertion during tha using a portable navigation system in patients with ddh. |
2024-04-25 |
2024-04-28 |
Not clear |
Masahiro Hasegawa, Yohei Naito, Shine Tone, Akihiro Sud. Comparison between accuracy of augmented reality computed tomography-based and portable augmented reality-based navigation systems for cup insertion in total hip arthroplasty. Scientific reports. vol 14. issue 1. 2024-04-09. PMID:38594498. |
comparison between accuracy of augmented reality computed tomography-based and portable augmented reality-based navigation systems for cup insertion in total hip arthroplasty. |
2024-04-09 |
2024-04-12 |
Not clear |
Masahiro Hasegawa, Yohei Naito, Shine Tone, Akihiro Sud. Comparison between accuracy of augmented reality computed tomography-based and portable augmented reality-based navigation systems for cup insertion in total hip arthroplasty. Scientific reports. vol 14. issue 1. 2024-04-09. PMID:38594498. |
this study compared the accuracy of cup insertion during tha using ar-ct-based and portable ar-based navigation systems. |
2024-04-09 |
2024-04-12 |
Not clear |
Masahiro Hasegawa, Yohei Naito, Shine Tone, Akihiro Sud. Comparison between accuracy of augmented reality computed tomography-based and portable augmented reality-based navigation systems for cup insertion in total hip arthroplasty. Scientific reports. vol 14. issue 1. 2024-04-09. PMID:38594498. |
the primary outcome of this study was the absolute difference between cup angles in the intraoperative navigation record and those measured on postoperative ct. |
2024-04-09 |
2024-04-12 |
Not clear |
Masahiro Hasegawa, Yohei Naito, Shine Tone, Akihiro Sud. Comparison between accuracy of augmented reality computed tomography-based and portable augmented reality-based navigation systems for cup insertion in total hip arthroplasty. Scientific reports. vol 14. issue 1. 2024-04-09. PMID:38594498. |
the secondary outcome was to determine the factors affecting the absolute value of the navigation error in radiographic inclination (ri) and radiographic anteversion (ra) of the cup, including sex, age, body mass index, left or right side, approach, and preoperative pelvic tilt. |
2024-04-09 |
2024-04-12 |
Not clear |
Masahiro Hasegawa, Yohei Naito, Shine Tone, Akihiro Sud. Comparison between accuracy of augmented reality computed tomography-based and portable augmented reality-based navigation systems for cup insertion in total hip arthroplasty. Scientific reports. vol 14. issue 1. 2024-04-09. PMID:38594498. |
no significant differences were observed in ri or ra of the cup between the two navigation systems (ri: p = 0.706; ra: p = 0.329). |
2024-04-09 |
2024-04-12 |
Not clear |
Masahiro Hasegawa, Yohei Naito, Shine Tone, Akihiro Sud. Comparison between accuracy of augmented reality computed tomography-based and portable augmented reality-based navigation systems for cup insertion in total hip arthroplasty. Scientific reports. vol 14. issue 1. 2024-04-09. PMID:38594498. |
in conclusion, there were no differences in the accuracy of cup insertion between the ar ct-based and portable ar-based navigation systems. |
2024-04-09 |
2024-04-12 |
Not clear |